Background and Aims: ElastPQ is a point shear wave elastography technique used to non-invasively assess liver fibrosis. We compared liver stiffness measurements (LSM) by ElastPQ and fibroscan transient elastography (F-TE) in a cohort of patients with non-alcoholic fatty liver disease (NAFLD). We further evaluated the performance of ElastPQ in a subgroup of patients with available liver histology. Materials and Methods: We included patients with NAFLD who presented in a dedicated multidisciplinary clinic. Anthropometric parameters, blood tests and elastography measurements were obtained using F-TE and ElastPQ as part of routine clinical care. Results: We enrolled 671 patients with NAFLD, mean age 55.8 ± 13 years, body mass index (BMI) 31.5 ± 5.7 kg/m2, 56.6% males, 41% diabetes, 53.7% hypertension, 68% dyslipidaemia. ElastPQ showed an excellent correlation with F-TE (Spearman's r = 0.80, p <.001), which was better for mild/moderate stages of fibrosis. Independent predictors of a >2 kPa discrepancy between the two techniques were a larger waist circumference and F-TE ≥10 kPa. In the subgroup of 159 patients with available histology, ElastPQ showed similar diagnostic accuracy with F-TE in staging liver fibrosis (ElastPQ area under the curves 0.84, 0.83, 0.86 and 0.95, for F ≥ 1, F ≥ 2, F ≥ 3 and F = 4 respectively). Optimal cut-off values of ElastPQ for individual fibrosis stages were lower than those of F-TE. Conclusions: ElastPQ shows an excellent correlation with F-TE in patients with NAFLD, which was better for lower LSM. The optimal cut-off values of ElastPQ are lower than those of F-TE for individual stages of fibrosis. ElastPQ has similar diagnostic accuracy to F-TE for all stages of fibrosis.

Comparison of point-shear wave elastography (ElastPQ) and transient elastography (FibroScan) for liver fibrosis staging in patients with non-alcoholic fatty liver disease / Roccarina, Davide; Iogna Prat, Laura; Pallini, Giada; Guerrero Misas, Marta; Buzzetti, Elena; Saffioti, Francesca; Aricò, Francesco M; Mantovani, Anna; Koutli, Evangelia; Goyale, Atul; Rosselli, Matteo; Luong, Tu Vinh; Pinzani, Massimo; Tsochatzis, Emmanuel A. - In: LIVER INTERNATIONAL. - ISSN 1478-3231. - ELETTRONICO. - 42:(2022), pp. 2195-2203. [10.1111/liv.15297]

Comparison of point-shear wave elastography (ElastPQ) and transient elastography (FibroScan) for liver fibrosis staging in patients with non-alcoholic fatty liver disease

Roccarina, Davide;Rosselli, Matteo;Pinzani, Massimo;
2022

Abstract

Background and Aims: ElastPQ is a point shear wave elastography technique used to non-invasively assess liver fibrosis. We compared liver stiffness measurements (LSM) by ElastPQ and fibroscan transient elastography (F-TE) in a cohort of patients with non-alcoholic fatty liver disease (NAFLD). We further evaluated the performance of ElastPQ in a subgroup of patients with available liver histology. Materials and Methods: We included patients with NAFLD who presented in a dedicated multidisciplinary clinic. Anthropometric parameters, blood tests and elastography measurements were obtained using F-TE and ElastPQ as part of routine clinical care. Results: We enrolled 671 patients with NAFLD, mean age 55.8 ± 13 years, body mass index (BMI) 31.5 ± 5.7 kg/m2, 56.6% males, 41% diabetes, 53.7% hypertension, 68% dyslipidaemia. ElastPQ showed an excellent correlation with F-TE (Spearman's r = 0.80, p <.001), which was better for mild/moderate stages of fibrosis. Independent predictors of a >2 kPa discrepancy between the two techniques were a larger waist circumference and F-TE ≥10 kPa. In the subgroup of 159 patients with available histology, ElastPQ showed similar diagnostic accuracy with F-TE in staging liver fibrosis (ElastPQ area under the curves 0.84, 0.83, 0.86 and 0.95, for F ≥ 1, F ≥ 2, F ≥ 3 and F = 4 respectively). Optimal cut-off values of ElastPQ for individual fibrosis stages were lower than those of F-TE. Conclusions: ElastPQ shows an excellent correlation with F-TE in patients with NAFLD, which was better for lower LSM. The optimal cut-off values of ElastPQ are lower than those of F-TE for individual stages of fibrosis. ElastPQ has similar diagnostic accuracy to F-TE for all stages of fibrosis.
2022
42
2195
2203
Goal 3: Good health and well-being
Roccarina, Davide; Iogna Prat, Laura; Pallini, Giada; Guerrero Misas, Marta; Buzzetti, Elena; Saffioti, Francesca; Aricò, Francesco M; Mantovani, Anna...espandi
File in questo prodotto:
File Dimensione Formato  
Liver International - 2022 - Roccarina - Comparison of point‐shear wave elastography ElastPQ and transient elastography .pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 873.91 kB
Formato Adobe PDF
873.91 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1411455
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 9
social impact