We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included. Accuracy was assessed by comparison with LVO. Intra- and inter-observer reproducibility of the off-line analysis were assessed. Forty-five neonates were included. RVO calculation with tip-PVD was more accurate than hinge-PVD in comparison with LVO, r2 0.712 versus 0.464, bias (95% limits of agreement) 1.4 mL/kg/min (−26–29 mL/kg/min) versus 61 mL/kg/min (−11–132 mL/kg/min), respectively. Both hinge-PVD and tip-PVD presented similar reproducibility, with an intra-observer bias (95% LOA) of 0.3 (−1.0–0.5) and –0.2 (−0.8–0.5) respectively, and an inter-observer bias of 0.1 (−1.3–1.6) and 0.1 (−1.4–1.6). RVO calculation using tip-PVD was more accurate than the conventional technique, with similar reproducibility.

Accuracy and Reproducibility of a Modified Echocardiographic Method for Right Ventricular Output Calculation in Neonates / Milocchi, Carlotta; Nogara, Silvia; Mazzuca, Giorgia; Runfola, Federica; Ciarcià, Martina; Corsini, Iuri; Ficial, Benjamim. - In: JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE. - ISSN 2308-3425. - ELETTRONICO. - 12:(2025), pp. 18.0-18.0. [10.3390/jcdd12010018]

Accuracy and Reproducibility of a Modified Echocardiographic Method for Right Ventricular Output Calculation in Neonates

Corsini, Iuri;
2025

Abstract

We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included. Accuracy was assessed by comparison with LVO. Intra- and inter-observer reproducibility of the off-line analysis were assessed. Forty-five neonates were included. RVO calculation with tip-PVD was more accurate than hinge-PVD in comparison with LVO, r2 0.712 versus 0.464, bias (95% limits of agreement) 1.4 mL/kg/min (−26–29 mL/kg/min) versus 61 mL/kg/min (−11–132 mL/kg/min), respectively. Both hinge-PVD and tip-PVD presented similar reproducibility, with an intra-observer bias (95% LOA) of 0.3 (−1.0–0.5) and –0.2 (−0.8–0.5) respectively, and an inter-observer bias of 0.1 (−1.3–1.6) and 0.1 (−1.4–1.6). RVO calculation using tip-PVD was more accurate than the conventional technique, with similar reproducibility.
2025
12
0
0
Milocchi, Carlotta; Nogara, Silvia; Mazzuca, Giorgia; Runfola, Federica; Ciarcià, Martina; Corsini, Iuri; Ficial, Benjamim
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1414433
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact