This work presents a GC–MS–MS–MS method for the direct determination of clenbuterol in human urine. The method 3 comprises a pretreatment procedure and the instrumental analysis of the derivatives performed by GC–MS (ion trap) with 3 electron impact ionization. The GC–MS analysis allows isolation and characterization of specific fragments from the 1 original (MS ) molecular structure, and in particular, those fragments originating from the precursor ion cluster (m/z5335– 2 337) characteristic of clenbuterol. The MS product fragment m/z5300 is in turn used as a further precursor fragment 3 4 giving rise to a MS spectrum specific for clenbuterol. MS fragmentation spectra were also investigated. However, further 3 4 fragmentation of MS product ions does not lead to functional MS spectra nor to any significant increase in the 3 signal-to-noise ratio. The sensitivity limit of the MS technique is lower than 0.2 mg/ l, with a linear range between 0.5 and 5 mg/ l, thus matching the basic requirements for antidoping analysis according to the guidelines of the International Olympic Committee. Due to its overall analytical performance, the method is presently being evaluated as a confirmation protocol to be followed to detect illicit clenbuterol administration to the athletes, and compared with reference GC–MS and GC–MS–MS techniques.

Rapid Determination of Diuretics in Human Urine by Gas Chromatography – Mass Spectrometry Following Microwave Assisted Derivatization / AMENDOLA L.; COLAMONICI C.; MAZZARINO M.; BOTRE', Francesco. - In: ANALYTICA CHIMICA ACTA. - ISSN 0003-2670. - STAMPA. - 475:(2003), pp. 125-136. [10.1016/S0003-2670(02)01223-0]

Rapid Determination of Diuretics in Human Urine by Gas Chromatography – Mass Spectrometry Following Microwave Assisted Derivatization

BOTRE', Francesco
2003

Abstract

This work presents a GC–MS–MS–MS method for the direct determination of clenbuterol in human urine. The method 3 comprises a pretreatment procedure and the instrumental analysis of the derivatives performed by GC–MS (ion trap) with 3 electron impact ionization. The GC–MS analysis allows isolation and characterization of specific fragments from the 1 original (MS ) molecular structure, and in particular, those fragments originating from the precursor ion cluster (m/z5335– 2 337) characteristic of clenbuterol. The MS product fragment m/z5300 is in turn used as a further precursor fragment 3 4 giving rise to a MS spectrum specific for clenbuterol. MS fragmentation spectra were also investigated. However, further 3 4 fragmentation of MS product ions does not lead to functional MS spectra nor to any significant increase in the 3 signal-to-noise ratio. The sensitivity limit of the MS technique is lower than 0.2 mg/ l, with a linear range between 0.5 and 5 mg/ l, thus matching the basic requirements for antidoping analysis according to the guidelines of the International Olympic Committee. Due to its overall analytical performance, the method is presently being evaluated as a confirmation protocol to be followed to detect illicit clenbuterol administration to the athletes, and compared with reference GC–MS and GC–MS–MS techniques.
2003
475
125
136
AMENDOLA L.; COLAMONICI C.; MAZZARINO M.; BOTRE', Francesco
File in questo prodotto:
File Dimensione Formato  
06 ACA_2003_a.pdf

Accesso chiuso

Licenza: Tutti i diritti riservati
Dimensione 261.01 kB
Formato Adobe PDF
261.01 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1418889
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 73
  • ???jsp.display-item.citation.isi??? 66
social impact