In this paper, the results of the energy renovation of a residential building, aimed at introducing it into a Renewable Energy Community (CER), are presented. A case study located in Florence (Italy) is discussed. Static and dynamic energy models have been used to evaluate the energy performance of the building, to compare different scenarios based on heat pumps (independent or centralised generator) and to evaluate them under the perspective of EPBD parameters. A comparison has been made concerning energy consumption and CO2 emissions. In its current state, the building presents an energy performance index of 129.8 kWh/(m2year) (class D). The energy refurbishment with heat pump (A4, 24.7 kWh/(m2year)) and VMC system (A4, 39.3 kWh/(m2year)) ensures a strong reduction in CO2 emissions, respectively 5.5 kg/(m2year) and 8.7 kg/(m2year) against 24.4 kg/(m2year) with the current gas fired boiler. The centralized heat pump configuration allows to further reduce the energy consumption. With the same thermal energy requirement, the results show a reduction of 14% of the power needs (without total recovery), thanks to the better sizing of the generator. Furthermore, the centralized heat pump opens a perspective of direct self-consumption of the energy product by the photovoltaic system into a CER configuration. The paper shows that the energy renovation with a heat pump is an effective way to reach the EPBD objectives and decarbonize the residential heating and cooling sector.

Scenarios for the energy renovation of a residential building / Malevolti G.; Rocchetti A.; Socci L.. - In: E3S WEB OF CONFERENCES. - ISSN 2267-1242. - ELETTRONICO. - 523:(2024), pp. 0-0. ( 53rd AiCARR International Conference on From NZEB to ZEB: The Buildings of the Next Decades for a Healthy and Sustainable Future ita 2024) [10.1051/e3sconf/202452301005].

Scenarios for the energy renovation of a residential building

Rocchetti A.;Socci L.
2024

Abstract

In this paper, the results of the energy renovation of a residential building, aimed at introducing it into a Renewable Energy Community (CER), are presented. A case study located in Florence (Italy) is discussed. Static and dynamic energy models have been used to evaluate the energy performance of the building, to compare different scenarios based on heat pumps (independent or centralised generator) and to evaluate them under the perspective of EPBD parameters. A comparison has been made concerning energy consumption and CO2 emissions. In its current state, the building presents an energy performance index of 129.8 kWh/(m2year) (class D). The energy refurbishment with heat pump (A4, 24.7 kWh/(m2year)) and VMC system (A4, 39.3 kWh/(m2year)) ensures a strong reduction in CO2 emissions, respectively 5.5 kg/(m2year) and 8.7 kg/(m2year) against 24.4 kg/(m2year) with the current gas fired boiler. The centralized heat pump configuration allows to further reduce the energy consumption. With the same thermal energy requirement, the results show a reduction of 14% of the power needs (without total recovery), thanks to the better sizing of the generator. Furthermore, the centralized heat pump opens a perspective of direct self-consumption of the energy product by the photovoltaic system into a CER configuration. The paper shows that the energy renovation with a heat pump is an effective way to reach the EPBD objectives and decarbonize the residential heating and cooling sector.
2024
E3S Web of Conferences
53rd AiCARR International Conference on From NZEB to ZEB: The Buildings of the Next Decades for a Healthy and Sustainable Future
ita
2024
Goal 7: Affordable and clean energy
Malevolti G.; Rocchetti A.; Socci L.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1432823
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact