Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
The Calorimetric Electron Telescope (CALET), launched to the International Space Station (ISS) in 2015 August and continuously operating since, measures cosmic-ray (CR) electrons, nuclei, and gamma rays. CALET, with its 27 radiation length deep Total Absorption Calorimeter, measures particle energy and allows for the measurement of spectra, secondary to primary ratios of the more abundant CR nuclei through 28Ni, while the main charge detector can measure ultra-heavy CR nuclei through 44Ru. The results for the abundances of elements from Z = 14 to Z = 44 relative to 26Fe over 7.5 yr of observation are presented here and compared to previous measurements from ACE-CRIS, SuperTIGER, and HEAO-3.
Detected Abundances of Nuclei Relative to 26Fe for Elements 14Si through 44Ru with CALET on the International Space Station / Adriani, O., Akaike, Y., Asano, K., Asaoka, Y., Berti, E., Betti, P., Bigongiari, G., Binns, W.R., Bongi, M., Brogi, P., Bruno, A., Cannady, N., Castellini, G., Checchia, C., Cherry, M.L., Collazuol, G., de Nolfo, G.A., Ebisawa, K., Ficklin, A.W., Fuke, H., et al.. - In: THE ASTROPHYSICAL JOURNAL. - ISSN 0004-637X. - ELETTRONICO. - 988:(2025), pp. 148.0-148.0. [10.3847/1538-4357/ade3cc]
Detected Abundances of Nuclei Relative to 26Fe for Elements 14Si through 44Ru with CALET on the International Space Station
Adriani, O.;Akaike, Y.;Asano, K.;Asaoka, Y.;Berti, E.;Betti, P.;Bigongiari, G.;Binns, W. R.;Bongi, M.;Brogi, P.;Bruno, A.;Cannady, N.;Castellini, G.;Checchia, C.;Cherry, M. L.;Collazuol, G.;de Nolfo, G. A.;Ebisawa, K.;Ficklin, A. W.;Fuke, H.;Gonzi, S.;Guzik, T. G.;Hams, T.;Hibino, K.;Ichimura, M.;Israel, M. H.;Kasahara, K.;Kataoka, J.;Kataoka, R.;Katayose, Y.;Kato, C.;Kawanaka, N.;Kawakubo, Y.;Kobayashi, K.;Kohri, K.;Krawczynski, H. S.;Krizmanic, J. F.;Maestro, P.;Marrocchesi, P. S.;Mattiazzi, M.;Messineo, A. M.;Mitchell, J. W.;Miyake, S.;Moiseev, A. A.;Mori, M.;Mori, N.;Motz, H. M.;Munakata, K.;Nakahira, S.;Nishimura, J.;Negro, M.;Okuno, S.;Ormes, J. F.;Ozawa, S.;Pacini, L.;Papini, P.;Rauch, B. F.;Ricciarini, S. B.;Sakai, K.;Sakamoto, T.;Sasaki, M.;Shimizu, Y.;Shiomi, A.;Spillantini, P.;Stolzi, F.;Sugita, S.;Sulaj, A.;Takita, M.;Tamura, T.;Terasawa, T.;Torii, S.;Tsunesada, Y.;Uchihori, Y.;Vannuccini, E.;Wefel, J. P.;Yamaoka, K.;Yanagita, S.;Yoshida, A.;Yoshida, K.;Zober, W. V.
2025
Abstract
The Calorimetric Electron Telescope (CALET), launched to the International Space Station (ISS) in 2015 August and continuously operating since, measures cosmic-ray (CR) electrons, nuclei, and gamma rays. CALET, with its 27 radiation length deep Total Absorption Calorimeter, measures particle energy and allows for the measurement of spectra, secondary to primary ratios of the more abundant CR nuclei through 28Ni, while the main charge detector can measure ultra-heavy CR nuclei through 44Ru. The results for the abundances of elements from Z = 14 to Z = 44 relative to 26Fe over 7.5 yr of observation are presented here and compared to previous measurements from ACE-CRIS, SuperTIGER, and HEAO-3.
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1432829
Citazioni
ND
6
3
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.