This study reports the measurement, using the Lambda-X PMTF and Lambda-X instruments, of the optical characteristics of three types of intraocular lenses (IOLs) and the subsequent analysis for evaluation and comparison. The optical characteristics of the lenses are evaluated through the Modulation Transfer Function (MTF) in Through Focus mode and with different pupil sizes. The USAF (United States Air Force) resolution target is also used to qualitatively assess the image reproduction at far, intermediate, and near distances, offering a visual representation of the IOLs’ capabilities. The results show different behavior of the lenses in the visual acuity at different distances. In addition, the data were used in combination with previously reported proposals to connect the MTF with postoperative visual acuity.

Quantification of IOLs’ characteristics through optical measurements: Indications for a pre-implantation vision assessment at different distances / Alessio Giorgetti, Federico Tommasi, Lorenzo Fini, Stefano Pelli, Rita Mencucci, Giovanni Romualdi, Massimo Gurioli, Stefano Cavalieri. - In: IL NUOVO CIMENTO C. - ISSN 2037-4909. - ELETTRONICO. - 48:(2025), pp. 262.0-262.0. [10.1393/ncc/i2025-25262-3]

Quantification of IOLs’ characteristics through optical measurements: Indications for a pre-implantation vision assessment at different distances

Alessio Giorgetti;Federico Tommasi
;
Lorenzo Fini;Stefano Pelli;Rita Mencucci;Giovanni Romualdi;Massimo Gurioli;Stefano Cavalieri
2025

Abstract

This study reports the measurement, using the Lambda-X PMTF and Lambda-X instruments, of the optical characteristics of three types of intraocular lenses (IOLs) and the subsequent analysis for evaluation and comparison. The optical characteristics of the lenses are evaluated through the Modulation Transfer Function (MTF) in Through Focus mode and with different pupil sizes. The USAF (United States Air Force) resolution target is also used to qualitatively assess the image reproduction at far, intermediate, and near distances, offering a visual representation of the IOLs’ capabilities. The results show different behavior of the lenses in the visual acuity at different distances. In addition, the data were used in combination with previously reported proposals to connect the MTF with postoperative visual acuity.
2025
48
0
0
Alessio Giorgetti, Federico Tommasi, Lorenzo Fini, Stefano Pelli, Rita Mencucci, Giovanni Romualdi, Massimo Gurioli, Stefano Cavalieri
File in questo prodotto:
File Dimensione Formato  
ncc13426.pdf

accesso aperto

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Creative commons
Dimensione 921.19 kB
Formato Adobe PDF
921.19 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1436496
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact