To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications.

Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices / Alfonso Savastano , Gloria Gambini , Maria Cristina Savastano , Matteo Mario Carlà , Clara Rizzo , Tomaso Caporossi , Emanuele Crincoli , Stanislao Rizzo. - In: VISION. - ISSN 2411-5150. - ELETTRONICO. - (2023), pp. 0-0.

Internal Tube Occlusion with An Easily Removable Non-Absorbable Double Suture: A Novel Surgical Technique Adjunct for Non-Valved Glaucoma Drainage Devices

Alfonso Savastano;Clara Rizzo;Tomaso Caporossi;Stanislao Rizzo
2023

Abstract

To describe a surgical variant for non-valved glaucoma drainage device implants using an easily removable non-absorbable double suture into the lumen of the tube. A retrospective, non-comparative case series of 10 patients who underwent a non-valved glaucoma drainage device implant with an endoluminal double-suture for refractory glaucoma. The sutures were easily removed postoperatively without the need for an operating room. Intraocular pressure, number of medications, and early and late complications were evaluated with a follow-up of 12 months. None of the eyes that underwent an operation developed early or late complications. The first endoluminal suture was removed in all eyes with a mean time of removal of 30 ± 7 days. The second suture was removed in all eyes with a mean time of removal of 90 ± 7 days. No complications were noted, either, after or during suture removal. The mean preoperative IOP was 27.3 ± 4.0 and the postoperative IOP, at the end of the follow-up, was 12.7 ± 1.4. At the end of the follow-up, six patients (60%) achieved complete success and four patients (40%) achieved qualified success. In conclusion, in our case series, the surgical variant allowed for a safe and gradual regulation of the flow during postoperative management. Considering the efficacy of non-valved glaucoma drainage devices, an improvement in the safety profile allows surgeons to broaden the surgical indications.
2023
0
0
Alfonso Savastano , Gloria Gambini , Maria Cristina Savastano , Matteo Mario Carlà , Clara Rizzo , Tomaso Caporossi , Emanuele Crincoli ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1436636
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact