This article describes the fabrication and characterization of a pH sensor for monitoring the wound status. The pH sensitive layer consists of a graphene oxide (GO) layer obtained by drop-casting 5 μl of GO dispersion onto the working electrode of a screen-printed substrate. Sensitivity was 31.8 mV/pH with an accuracy of 0.3 unit of pH. Open-circuit potentiometry was carried out to measure pH in an exudate sample. The GO pH sensor proved to be reliable as the comparison with results obtained from a standard glass electrode pH-meter showed negligible differences (< 0.09 pH units in the worst case) for measurements performed over a period of 4 days.

A graphene oxide pH sensor for wound monitoring / MELAI, BERNARDO; SALVO, PIETRO; CALISI, NICOLA; Moni, L.; Bonini, A.; PAOLETTI, CLARA; LOMONACO, TOMMASO; MOLLICA, VINCENZO; FUOCO, ROGER; DI FRANCESCO, FABIO. - STAMPA. - 2016:(2016), pp. 1898-1901. ( 38th Annual International Conference of the Engineering in Medicine and Biology Society (EMBC) Orlando (Florida, USA) 16/08/2016 - 20/08/2016) [10.1109/EMBC.2016.7591092].

A graphene oxide pH sensor for wound monitoring

CALISI, NICOLA;Bonini, A.;
2016

Abstract

This article describes the fabrication and characterization of a pH sensor for monitoring the wound status. The pH sensitive layer consists of a graphene oxide (GO) layer obtained by drop-casting 5 μl of GO dispersion onto the working electrode of a screen-printed substrate. Sensitivity was 31.8 mV/pH with an accuracy of 0.3 unit of pH. Open-circuit potentiometry was carried out to measure pH in an exudate sample. The GO pH sensor proved to be reliable as the comparison with results obtained from a standard glass electrode pH-meter showed negligible differences (< 0.09 pH units in the worst case) for measurements performed over a period of 4 days.
2016
Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference of the
38th Annual International Conference of the Engineering in Medicine and Biology Society (EMBC)
Orlando (Florida, USA)
16/08/2016 - 20/08/2016
MELAI, BERNARDO; SALVO, PIETRO; CALISI, NICOLA; Moni, L.; Bonini, A.; PAOLETTI, CLARA; LOMONACO, TOMMASO; MOLLICA, VINCENZO; FUOCO, ROGER; DI FRANCESC...espandi
File in questo prodotto:
File Dimensione Formato  
A graphene oxide pH sensor for wound monitoring.pdf

Accesso chiuso

Licenza: Tutti i diritti riservati
Dimensione 698.54 kB
Formato Adobe PDF
698.54 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1438466
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 33
social impact