Detailed kinetic studies during the cationic ring-opening polymerization (CROP) of 2-ethyl-2-oxazoline (EtOx) are conducted using four bifunctional bromo-type initiators in N,N-dimethylformamide (DMF) at 140 °C. Serving as models to quantify chain transfer to monomer occurring during the CROP initiated by monofunctional initiators, size exclusion chromatography (SEC) resolves a second molar mass distribution with lower molar mass at initial [monomer] to [initiation site] ratios ([M]0/[I]0) of 25, while the resolution is insufficient at [M]0/[I]0 of 10. Slightly slow initiation is revealed at [M]0/[I]0 = 25, which prohibits the derivation of chain transfer rates by fitting of the size exclusion chromatography (SEC) data. Although conventional kinetic plots give no indication of significant amounts of chain transfer, the molar mass distributions resolved by SEC can unambiguously be identified as such by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) in both the high as well as the low m/z regions of the mass spectra.
Bifunctional Initiators as Tools to Track Chain Transfer during the CROP of 2‐Oxazolines / Sahn, Martin; Bandelli, Damiano; Dirauf, Michael; Weber, Christine; Schubert, Ulrich S.. - In: MACROMOLECULAR RAPID COMMUNICATIONS. - ISSN 1022-1336. - ELETTRONICO. - 38:(2017), pp. 1700396.0-1700396.0. [10.1002/marc.201700396]
Bifunctional Initiators as Tools to Track Chain Transfer during the CROP of 2‐Oxazolines
Bandelli, Damiano;
2017
Abstract
Detailed kinetic studies during the cationic ring-opening polymerization (CROP) of 2-ethyl-2-oxazoline (EtOx) are conducted using four bifunctional bromo-type initiators in N,N-dimethylformamide (DMF) at 140 °C. Serving as models to quantify chain transfer to monomer occurring during the CROP initiated by monofunctional initiators, size exclusion chromatography (SEC) resolves a second molar mass distribution with lower molar mass at initial [monomer] to [initiation site] ratios ([M]0/[I]0) of 25, while the resolution is insufficient at [M]0/[I]0 of 10. Slightly slow initiation is revealed at [M]0/[I]0 = 25, which prohibits the derivation of chain transfer rates by fitting of the size exclusion chromatography (SEC) data. Although conventional kinetic plots give no indication of significant amounts of chain transfer, the molar mass distributions resolved by SEC can unambiguously be identified as such by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) in both the high as well as the low m/z regions of the mass spectra.| File | Dimensione | Formato | |
|---|---|---|---|
|
Macromolecular Rapid Communications - 2017 - Sahn - Bifunctional Initiators as Tools to Track Chain Transfer during the.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Open Access
Dimensione
1.63 MB
Formato
Adobe PDF
|
1.63 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



