Abstract. To assist the design of ground heat exchangers the thermal response test method is usually performed. In its traditional version the thermal response test data are compared with the line source model solution to restore the soil thermal conductivity and the borehole thermal resistance. This approach requires that a steady-state thermal condition is approached and, consequently, it may need up to about 50 hours to be carried out. Promising approaches can be found within parameter estimation procedures supported by 3-D numerical tools. They allow the reduction of the test duration, since they perform a more realistic description of the system’s behaviour especially in the early regime. In this paper, a versatile parameter estimation procedure based on a 3-D numerical model of a geothermal system is presented. The procedure is aimed to restore the value of both the soil thermal conductivity and the borehole thermal resistance, by using only the first few hours of the thermal response test data. The approach is validated by comparison with a medium-scale set of experimental laboratory data.

Short-time thermal response test based on a 3-D numerical model / F. Bozzoli; G. Pagliarini; S. Rainieri; L. Schiavi. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6596. - 395:(2012), pp. 1-7. [10.1088/1742-6596/395/1/012056]

Short-time thermal response test based on a 3-D numerical model

F. Bozzoli;
2012

Abstract

Abstract. To assist the design of ground heat exchangers the thermal response test method is usually performed. In its traditional version the thermal response test data are compared with the line source model solution to restore the soil thermal conductivity and the borehole thermal resistance. This approach requires that a steady-state thermal condition is approached and, consequently, it may need up to about 50 hours to be carried out. Promising approaches can be found within parameter estimation procedures supported by 3-D numerical tools. They allow the reduction of the test duration, since they perform a more realistic description of the system’s behaviour especially in the early regime. In this paper, a versatile parameter estimation procedure based on a 3-D numerical model of a geothermal system is presented. The procedure is aimed to restore the value of both the soil thermal conductivity and the borehole thermal resistance, by using only the first few hours of the thermal response test data. The approach is validated by comparison with a medium-scale set of experimental laboratory data.
2012
395
1
7
F. Bozzoli; G. Pagliarini; S. Rainieri; L. Schiavi
File in questo prodotto:
File Dimensione Formato  
Eurotherm2012_bhe.pdf

Accesso chiuso

Licenza: Tutti i diritti riservati
Dimensione 944.43 kB
Formato Adobe PDF
944.43 kB Adobe PDF   Richiedi una copia