Background: Among no-touch automated disinfection devices, ultraviolet-C (UV-C) radiation has been proven to be one of the most effective against a broad spectrum of micro-organisms causing healthcare-associated infections. Aim: To evaluate the antimicrobial efficacy of an experimental UV-C robotic platform, under controlled conditions and in a real hospital scenario, when used to implement the standard cleaning operating protocol (SOP). Methods: In vitro, following dose calibration tests, bactericidal and virucidal efficacy were tested in accordance with American Society for Testing and Materials International Standard E3135-18. In hospital settings, 12 high-touch surfaces were sampled after healthcare activity (dirty condition), after SOP alone, and after SOP + UV-C treatment, with a total of 180 samples. Findings: In vitro, <4 mJ/cm2 was required to remove Staphylococcus aureus and Pseudomonas aeruginosa completely, 194 mJ/cm2 was required to inactivate adenovirus HadV5 completely, and 38.8 mJ/cm2 was sufficient to inactivate coronavirus 229E completely. In the real hospital scenario, the mean UV-C dose emitted on the sampled surfaces was 29.31 mJ/cm2. A significant difference was found after SOP alone (P=0.022) and after SOP + UV-C treatment (P=0.007) compared with the dirty condition. The average percentage reduction in the total viable count (TVC) was 67% after SOP alone and 96% after SOP + UV-C treatment. Conclusions: Comparison of the tests conducted in vitro and in the real hospital scenario showed that the efficacy of the UV-C robot was reduced in the hospital setting, as a higher dose was needed to obtain a reduction in the TVC.
Antimicrobial efficacy of an experimental UV-C robot in controlled conditions and in a real hospital scenario / Casini, B.; Scarpaci, M.; Chiovelli, F.; Leonetti, S.; Costa, A.L.; Baroni, M.; Petrillo, M.; Cavallo, F.. - In: THE JOURNAL OF HOSPITAL INFECTION. - ISSN 0195-6701. - ELETTRONICO. - 156:(2025), pp. 72-77. [10.1016/j.jhin.2024.11.010]
Antimicrobial efficacy of an experimental UV-C robot in controlled conditions and in a real hospital scenario
Cavallo, F.Data Curation
2025
Abstract
Background: Among no-touch automated disinfection devices, ultraviolet-C (UV-C) radiation has been proven to be one of the most effective against a broad spectrum of micro-organisms causing healthcare-associated infections. Aim: To evaluate the antimicrobial efficacy of an experimental UV-C robotic platform, under controlled conditions and in a real hospital scenario, when used to implement the standard cleaning operating protocol (SOP). Methods: In vitro, following dose calibration tests, bactericidal and virucidal efficacy were tested in accordance with American Society for Testing and Materials International Standard E3135-18. In hospital settings, 12 high-touch surfaces were sampled after healthcare activity (dirty condition), after SOP alone, and after SOP + UV-C treatment, with a total of 180 samples. Findings: In vitro, <4 mJ/cm2 was required to remove Staphylococcus aureus and Pseudomonas aeruginosa completely, 194 mJ/cm2 was required to inactivate adenovirus HadV5 completely, and 38.8 mJ/cm2 was sufficient to inactivate coronavirus 229E completely. In the real hospital scenario, the mean UV-C dose emitted on the sampled surfaces was 29.31 mJ/cm2. A significant difference was found after SOP alone (P=0.022) and after SOP + UV-C treatment (P=0.007) compared with the dirty condition. The average percentage reduction in the total viable count (TVC) was 67% after SOP alone and 96% after SOP + UV-C treatment. Conclusions: Comparison of the tests conducted in vitro and in the real hospital scenario showed that the efficacy of the UV-C robot was reduced in the hospital setting, as a higher dose was needed to obtain a reduction in the TVC.| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S019567012400389X-main.pdf
Accesso chiuso
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
383.1 kB
Formato
Adobe PDF
|
383.1 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.