Biological experiments in space and ongoing human space missions devoted to the solar system exploration require significant advancements in the radiation environment monitoring systems. Radiation hazard has to be continuously monitored and the biological damage should be evaluated within short time. In this paper, we review the use of polycrystalline diamond films as dosimeters for space applications. The charge trapped into deep intra-gap defect levels during radiation exposure, and released during a high-temperature thermal scan to give thermally stimulated current (TSC), has been integrated as a function of time to evaluate the absorbed dose. TSC results have been proved to give correct evaluation of the dose absorbed during the space mission, assessing the capabilities of synthetic diamond and TSC read-out system as a proper dosimetry technique for space applications. The capability of diamond films to detect low doses has been demonstrated down to the mGys range. The results of the application of these dosimeters in low Earth orbit space missions are described. © Accademia Nazionale dei Lincei 2014.

Diamond dosimeters: applications to radiobiology and space environments / Pace, Emanuele; De Sio, Antonio; Tozzetti, Lorenzo; Bruzzi, Mara. - In: RENDICONTI LINCEI. SCIENZE FISICHE E NATURALI. - ISSN 2037-4631. - STAMPA. - 25:(2014), pp. 87-90. [10.1007/s12210-014-0296-y]

Diamond dosimeters: applications to radiobiology and space environments

Pace, Emanuele;De Sio, Antonio;Bruzzi, Mara
2014

Abstract

Biological experiments in space and ongoing human space missions devoted to the solar system exploration require significant advancements in the radiation environment monitoring systems. Radiation hazard has to be continuously monitored and the biological damage should be evaluated within short time. In this paper, we review the use of polycrystalline diamond films as dosimeters for space applications. The charge trapped into deep intra-gap defect levels during radiation exposure, and released during a high-temperature thermal scan to give thermally stimulated current (TSC), has been integrated as a function of time to evaluate the absorbed dose. TSC results have been proved to give correct evaluation of the dose absorbed during the space mission, assessing the capabilities of synthetic diamond and TSC read-out system as a proper dosimetry technique for space applications. The capability of diamond films to detect low doses has been demonstrated down to the mGys range. The results of the application of these dosimeters in low Earth orbit space missions are described. © Accademia Nazionale dei Lincei 2014.
2014
25
87
90
Pace, Emanuele; De Sio, Antonio; Tozzetti, Lorenzo; Bruzzi, Mara
File in questo prodotto:
File Dimensione Formato  
s12210-014-0296-y.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Solo lettura
Dimensione 623.7 kB
Formato Adobe PDF
623.7 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1450814
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact