Objectives: To verify the feasibility of the Virtual Eggs Test (VET) and establish the ranges of fragilities of the Virtual Eggs (VEs) for assessing dexterity of stroke subjects and to collect feedback to improve its usability. Methods: An observational non-profit study, with a pre-market medical device. It was conducted at a hospital neurorehabilitation unit. Nine subjects with chronic stroke (5 males; mean age 55.8 ± 18.9) performed the pilot with their paretic arm. Time to complete the test (TT), the number of failures for each VE, the threshold (T), and participants’ self-reported comfort in performing the test were measured. Results: The T varied among participants from 1.70 to 4.88 N/N. The average TT was 20.1 ± 6.5 minutes (range 11-33). Only one subject found the test uncomfortable. Conclusions: The study found that the VET, with minor modifications, is feasible in stroke subjects. It might be useful for assessing sensorimotor impairment in both the affected and the less affected arm. Its metric properties and normative values in the healthy population will be determined in a study currently underway.

Application and adaptation of the Virtual Eggs Test for assessing hand dexterity in subjects with stroke: a pilot study / Piazzini, Michele; Angelini, Lucia; Ciapetti, Tommaso; Doronzio, Stefano; Baccini, Marco; Guachi, Robinson; Mucci, Paola; Controzzi, Marco; Cecchi, Francesca. - In: ARCHIVES OF PHYSIOTHERAPY. - ISSN 2057-0082. - ELETTRONICO. - 15:(2025), pp. 131-137. [10.33393/aop.2025.3291]

Application and adaptation of the Virtual Eggs Test for assessing hand dexterity in subjects with stroke: a pilot study

Piazzini, Michele;Angelini, Lucia;Doronzio, Stefano;Baccini, Marco;Cecchi, Francesca
Conceptualization
2025

Abstract

Objectives: To verify the feasibility of the Virtual Eggs Test (VET) and establish the ranges of fragilities of the Virtual Eggs (VEs) for assessing dexterity of stroke subjects and to collect feedback to improve its usability. Methods: An observational non-profit study, with a pre-market medical device. It was conducted at a hospital neurorehabilitation unit. Nine subjects with chronic stroke (5 males; mean age 55.8 ± 18.9) performed the pilot with their paretic arm. Time to complete the test (TT), the number of failures for each VE, the threshold (T), and participants’ self-reported comfort in performing the test were measured. Results: The T varied among participants from 1.70 to 4.88 N/N. The average TT was 20.1 ± 6.5 minutes (range 11-33). Only one subject found the test uncomfortable. Conclusions: The study found that the VET, with minor modifications, is feasible in stroke subjects. It might be useful for assessing sensorimotor impairment in both the affected and the less affected arm. Its metric properties and normative values in the healthy population will be determined in a study currently underway.
2025
15
131
137
Piazzini, Michele; Angelini, Lucia; Ciapetti, Tommaso; Doronzio, Stefano; Baccini, Marco; Guachi, Robinson; Mucci, Paola; Controzzi, Marco; Cecchi, Fr...espandi
File in questo prodotto:
File Dimensione Formato  
aop_3291+supplementary+material.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 440.67 kB
Formato Adobe PDF
440.67 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1451679
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact