Background/Objectives: Accurate post-mortem interval (PMI) estimation remains challenging in forensic pathology. Although potassium (K+) is the most well-validated single biomarker in vitreous humor (VH), multivariate approaches may enhance precision by capturing the complex cascade of post-mortem biochemical changes. This study aimed to develop and validate a multivariate PMI estimation model incorporating three biochemical markers—potassium, ammonium (NH4+), and albumin (ALB)—in vitreous humor using automated clinical chemistry platforms for practical forensic application. Methods: Vitreous humor samples from 38 autopsy cases with documented PMIs (39.5–285 h; mean, 105.5 h) were analyzed for K+ (Cobas C8000), NH4+ (Cobas C8000), and ALB (Immage 800 nephelometry). Univariate and multivariate regression analyses were performed, with the residual standard error (RSE) as the primary measure of accuracy. Model validation was conducted by back-calculating PMI in four samples completely distinct from the training cohort. Results: All three analytes demonstrated strong individual correlations with PMI (R2: K+ = 0.88, ALB = 0.78, NH4+ = 0.69; all p < 0.001). The multivariate regression model [PMI = 40.25[Alb] + 0.01573[NH4+] + 5.339[K+] − 53.032] yielded an RMSE of ±15.5 h (MSE = 240.25 h2), outperforming potassium-only models (RMSE = ±22.6 h). Although NH4+ showed limited statistical significance in the multivariate model (p = 0.128), its inclusion improved overall predictive accuracy. External validation in an independent cohort of four subjects (distinct from the 38 subjects in the training set) demonstrated a mean absolute error (MAE) of 20.4 h. Conclusions: The multivariate approach combining K+, NH4+, and ALB in VH improves PMI estimation accuracy compared with single-marker methods. The use of automated clinical chemistry platforms enhances reproducibility and facilitates practical implementation in forensic laboratories.

A Step Forward in Post-Mortem Interval Estimation: Multivariate Analysis of Ammonium, Albumin, and Potassium Levels in Vitreous Humor / Focardi, M., Defraia, B., Bianchi, I., Gualco, B., Costantino, A., Grifoni, R., Fanelli, A., Biagioli, T., Bossi, C., Pinchi, V., Lanzilao, L.. - In: DIAGNOSTICS. - ISSN 2075-4418. - STAMPA. - 16:(2026), pp. 1-15. [10.3390/diagnostics16131970]

A Step Forward in Post-Mortem Interval Estimation: Multivariate Analysis of Ammonium, Albumin, and Potassium Levels in Vitreous Humor

Focardi, Martina;Defraia, Beatrice;Bianchi, Ilenia
;
Gualco, Barbara;Costantino, Andrea;Grifoni, Rossella;Fanelli, Alessandra;Biagioli, Tiziana;Bossi, Costanza;Pinchi, Vilma;Lanzilao, Luisa
2026

Abstract

Background/Objectives: Accurate post-mortem interval (PMI) estimation remains challenging in forensic pathology. Although potassium (K+) is the most well-validated single biomarker in vitreous humor (VH), multivariate approaches may enhance precision by capturing the complex cascade of post-mortem biochemical changes. This study aimed to develop and validate a multivariate PMI estimation model incorporating three biochemical markers—potassium, ammonium (NH4+), and albumin (ALB)—in vitreous humor using automated clinical chemistry platforms for practical forensic application. Methods: Vitreous humor samples from 38 autopsy cases with documented PMIs (39.5–285 h; mean, 105.5 h) were analyzed for K+ (Cobas C8000), NH4+ (Cobas C8000), and ALB (Immage 800 nephelometry). Univariate and multivariate regression analyses were performed, with the residual standard error (RSE) as the primary measure of accuracy. Model validation was conducted by back-calculating PMI in four samples completely distinct from the training cohort. Results: All three analytes demonstrated strong individual correlations with PMI (R2: K+ = 0.88, ALB = 0.78, NH4+ = 0.69; all p < 0.001). The multivariate regression model [PMI = 40.25[Alb] + 0.01573[NH4+] + 5.339[K+] − 53.032] yielded an RMSE of ±15.5 h (MSE = 240.25 h2), outperforming potassium-only models (RMSE = ±22.6 h). Although NH4+ showed limited statistical significance in the multivariate model (p = 0.128), its inclusion improved overall predictive accuracy. External validation in an independent cohort of four subjects (distinct from the 38 subjects in the training set) demonstrated a mean absolute error (MAE) of 20.4 h. Conclusions: The multivariate approach combining K+, NH4+, and ALB in VH improves PMI estimation accuracy compared with single-marker methods. The use of automated clinical chemistry platforms enhances reproducibility and facilitates practical implementation in forensic laboratories.
2026
16
1
15
Goal 16: Peace, justice and strong institutions
Focardi, Martina; Defraia, Beatrice; Bianchi, Ilenia; Gualco, Barbara; Costantino, Andrea; Grifoni, Rossella; Fanelli, Alessandra; Biagioli, Tiziana; ...espandi
File in questo prodotto:
File Dimensione Formato  
diagnostics-16-01970.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 445.44 kB
Formato Adobe PDF
445.44 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1476893
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact