This paper presents a thermo-economic analysis of closed-loop borehole heat exchanger systems, investigating their feasibility for both direct thermal applications and heat and power cogeneration. A specific focus is placed on two Italian case studies: a residential district heating application in Gavorrano and an industrial/agricultural application in the Mt. Amiata area. A numerical model was developed to optimize the system components, including a novel cost correlation for Organic Rankine Cycle units operating under off-design conditions with well flow rates ranging between 50 and 300 kg/s. The results highlight the critical influence of geological characteristics and drilling costs on economic viability. Both applications proved to be generally in line with similar technologies in Europe from an economic point of view. In particular, the Mt. Amiata case study demonstrated significant economic potential, achieving a Levelized Cost of Heat of 0.1161 €/kWh for a 15-well configuration and 0.1462 €/kWh for a 20-well configuration. These findings suggest that borehole heat exchanger systems can be a cost-effective solution for decarbonizing industrial heat sectors in suitable geothermal settings.
Closed-loop borehole heat exchanger systems: Insights from two Italian case studies / Ungar, P., Gigliotti, F., Falchini, E., Fiaschi, D.. - In: RENEWABLE ENERGY. - ISSN 0960-1481. - ELETTRONICO. - 276:(2026), pp. 126340.1-126340.20. [10.1016/j.renene.2026.126340]
Closed-loop borehole heat exchanger systems: Insights from two Italian case studies
Ungar, Pietro;Gigliotti, Federico;Falchini, Edoardo;Fiaschi, Daniele
2026
Abstract
This paper presents a thermo-economic analysis of closed-loop borehole heat exchanger systems, investigating their feasibility for both direct thermal applications and heat and power cogeneration. A specific focus is placed on two Italian case studies: a residential district heating application in Gavorrano and an industrial/agricultural application in the Mt. Amiata area. A numerical model was developed to optimize the system components, including a novel cost correlation for Organic Rankine Cycle units operating under off-design conditions with well flow rates ranging between 50 and 300 kg/s. The results highlight the critical influence of geological characteristics and drilling costs on economic viability. Both applications proved to be generally in line with similar technologies in Europe from an economic point of view. In particular, the Mt. Amiata case study demonstrated significant economic potential, achieving a Levelized Cost of Heat of 0.1161 €/kWh for a 15-well configuration and 0.1462 €/kWh for a 20-well configuration. These findings suggest that borehole heat exchanger systems can be a cost-effective solution for decarbonizing industrial heat sectors in suitable geothermal settings.| File | Dimensione | Formato | |
|---|---|---|---|
|
Closed-loop borehole heat exchanger systems-Insights from two Italian case studies.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
6.36 MB
Formato
Adobe PDF
|
6.36 MB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.