This paper investigates fat tissue as a medium for communication in implantable/ingestible medical device (IMD) systems based on optical wireless communication (OWC). The findings emphasize the importance of tissue characteristics (temperature in particular) for optimizing OWC performance. This study considered Near-infrared (NIR) light with 810 nm wavelength and fresh porcine samples to mimic the human tissue. The study employs a realistic measurement approach in an ex vivo setting using various porcine samples: pure fat and flesh tissues and samples with different thicknesses. This study also investigates the influence of porcine temperature on the optical communication channels, which are measured by comparing the received optical power at 23 °C and 37 °C. In general, tissue samples at warmer temperatures (37 °C) receive higher optical power than colder samples. The results also demonstrate the superior optical power transmission capabilities of pure fat compared to pure flesh in porcine tissue samples in warm conditions. We also found that porcine with multiple layers of fat (fatty sample) yields higher received optical power than porcine with multiple layers of flesh (muscular). The results of this study provide valuable insights and relevant considerations for OWC-based in-body communication conducted using porcine samples.

Study on Fat as the Propagation Medium in Optical-Based In-Body Communications / Fuada S., Sarestoniemi M., Katz M., Soderi S., Hamalainen M.. - 2084:(2024), pp. 467-479. (1st Nordic Conference on Digital Health and Wireless Solutions, NCDHWS 2024 Oulu, Finland May 7-8, 2024) [10.1007/978-3-031-59091-7_31].

Study on Fat as the Propagation Medium in Optical-Based In-Body Communications

Soderi S.;
2024

Abstract

This paper investigates fat tissue as a medium for communication in implantable/ingestible medical device (IMD) systems based on optical wireless communication (OWC). The findings emphasize the importance of tissue characteristics (temperature in particular) for optimizing OWC performance. This study considered Near-infrared (NIR) light with 810 nm wavelength and fresh porcine samples to mimic the human tissue. The study employs a realistic measurement approach in an ex vivo setting using various porcine samples: pure fat and flesh tissues and samples with different thicknesses. This study also investigates the influence of porcine temperature on the optical communication channels, which are measured by comparing the received optical power at 23 °C and 37 °C. In general, tissue samples at warmer temperatures (37 °C) receive higher optical power than colder samples. The results also demonstrate the superior optical power transmission capabilities of pure fat compared to pure flesh in porcine tissue samples in warm conditions. We also found that porcine with multiple layers of fat (fatty sample) yields higher received optical power than porcine with multiple layers of flesh (muscular). The results of this study provide valuable insights and relevant considerations for OWC-based in-body communication conducted using porcine samples.
2024
Communications in Computer and Information Science
1st Nordic Conference on Digital Health and Wireless Solutions, NCDHWS 2024
Oulu, Finland
May 7-8, 2024
Fuada S.; Sarestoniemi M.; Katz M.; Soderi S.; Hamalainen M.
File in questo prodotto:
File Dimensione Formato  
978-3-031-59091-7_31.pdf

Accesso chiuso

Licenza: Tutti i diritti riservati
Dimensione 2.12 MB
Formato Adobe PDF
2.12 MB Adobe PDF   Richiedi una copia all'autore

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1499179
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact