Background: Aortic dilation (AoD) is commonly reported in patients with bicuspid aortic valve (BAV) and has been related to flow abnormalities and genetic predisposition. AoD-related complications are reported to be extremely rare in children. Conversely, an overestimate of AoD related to body size may lead to excess diagnoses and negatively impact quality of life and an active lifestyle. In the present study, we compared the diagnosis performance of the newly introduced Q-score (based on a machine-learning algorithm) versus the traditional Z-score in a large consecutive pediatric cohort with BAV. Materials and methods: Prevalence and progression of AoD were evaluated in 281 pediatric patients ages > 5 and < 18 years at first observation, 249 of whom had isolated BAV and 32 had BAV associated with aortic coarctation (CoA–BAV). An additional group of 24 pediatric patients with isolated CoA was considered. Measurements were made at the level of the aortic annulus, Valsalva sinuses, sinotubular aorta, and proximal ascending aorta. Both Z-scores using traditional nomograms and the new Q-score were calculated at baseline and at followup (mean 4.5 years). Results: A dilation of the proximal ascending aorta was suggested by traditional nomograms (Z-score > 2) in 31.2% of patients with isolated BAV and 18.5% with CoA–BAV at baseline and in 40.7% and 33.3%, respectively, at followup. Finally, the nomograms used may significantly influence the prevalence of AoD, especially in children, with a possible overestimation by traditional nomograms. This concept requires prospective validation in long-term followup.

Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence / Spaziani G., Bonanni F., Girolami F., Bennati E., Calabri G.B., Di Filippo C., Porcedda G., Passantino S., Nistri S., Olivotto I., Favilli S.. - In: DIAGNOSTICS. - ISSN 2075-4418. - ELETTRONICO. - 13:(2023), pp. 1490.0-1490.0. [10.3390/diagnostics13081490]

Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence

Spaziani G.;Girolami F.;Bennati E.;Di Filippo C.;Passantino S.;Olivotto I.;Favilli S.
2023

Abstract

Background: Aortic dilation (AoD) is commonly reported in patients with bicuspid aortic valve (BAV) and has been related to flow abnormalities and genetic predisposition. AoD-related complications are reported to be extremely rare in children. Conversely, an overestimate of AoD related to body size may lead to excess diagnoses and negatively impact quality of life and an active lifestyle. In the present study, we compared the diagnosis performance of the newly introduced Q-score (based on a machine-learning algorithm) versus the traditional Z-score in a large consecutive pediatric cohort with BAV. Materials and methods: Prevalence and progression of AoD were evaluated in 281 pediatric patients ages > 5 and < 18 years at first observation, 249 of whom had isolated BAV and 32 had BAV associated with aortic coarctation (CoA–BAV). An additional group of 24 pediatric patients with isolated CoA was considered. Measurements were made at the level of the aortic annulus, Valsalva sinuses, sinotubular aorta, and proximal ascending aorta. Both Z-scores using traditional nomograms and the new Q-score were calculated at baseline and at followup (mean 4.5 years). Results: A dilation of the proximal ascending aorta was suggested by traditional nomograms (Z-score > 2) in 31.2% of patients with isolated BAV and 18.5% with CoA–BAV at baseline and in 40.7% and 33.3%, respectively, at followup. Finally, the nomograms used may significantly influence the prevalence of AoD, especially in children, with a possible overestimation by traditional nomograms. This concept requires prospective validation in long-term followup.
2023
13
0
0
Goal 3: Good health and well-being
Spaziani G.; Bonanni F.; Girolami F.; Bennati E.; Calabri G.B.; Di Filippo C.; Porcedda G.; Passantino S.; Nistri S.; Olivotto I.; Favilli S.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1499575
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact