Pallet racking systems are a peculiar construction system within structural engineering. They are made of cold-formed thin-walled steel profiles and are characterized by a high ratio of live loads to self-weight. The global behaviour of these structures is complex, governed by the nonlinearity of their semi-rigid connections, by their sensitivity to second-order effects and to local and distortional buckling phenomena. Within this framework, the experimental assessment of structural capacity and collapse mechanisms plays a key role both for safety verification and for structural design. This contribution presents the preliminary results of an experimental campaign carried out on representative pallet rack configurations subjected to nonlinear static pushover tests. The research focuses on the evaluation of the seismic capacity and structural response in the longitudinal (down-aisle) direction, where global stability relies primarily on the behaviour of moment-resisting frames formed by uprights and beams connected through dry connections. The aim of the research is to identify the system response through the analysis of experimental capacity curves and the identification of ductility and behaviour (q-factor) parameters. In addition to tests on the unstrengthened configuration (reference configuration), the experimental program also investigates the effectiveness of local strengthening details applied to the beam-to-upright connections, with the goal of increasing frame stiffness and displacement capacity. The experimental results provide a basis for a qualitative and comparative discussion of the influence of the strengthening solutions on global capacity, ductility, and system stability, highlighting critical aspects related to connection response and second-order effects.
Preliminary Results from Pushover Tests on Pallet Racks with Strengthened Beam-to-Upright Connections / Mei, A., Lavacchini, G., Matteini, F., Orlando, M.. - ELETTRONICO. - 942:(2026), pp. 334-345. (30th Congress of the Italian College of Steel Technicians, CTA 2026 ita 2026) [10.1007/978-3-032-39505-4_29].
Preliminary Results from Pushover Tests on Pallet Racks with Strengthened Beam-to-Upright Connections
Mei, Alessandro;Lavacchini, Giovanni;Matteini, Francesca;Orlando, Maurizio
2026
Abstract
Pallet racking systems are a peculiar construction system within structural engineering. They are made of cold-formed thin-walled steel profiles and are characterized by a high ratio of live loads to self-weight. The global behaviour of these structures is complex, governed by the nonlinearity of their semi-rigid connections, by their sensitivity to second-order effects and to local and distortional buckling phenomena. Within this framework, the experimental assessment of structural capacity and collapse mechanisms plays a key role both for safety verification and for structural design. This contribution presents the preliminary results of an experimental campaign carried out on representative pallet rack configurations subjected to nonlinear static pushover tests. The research focuses on the evaluation of the seismic capacity and structural response in the longitudinal (down-aisle) direction, where global stability relies primarily on the behaviour of moment-resisting frames formed by uprights and beams connected through dry connections. The aim of the research is to identify the system response through the analysis of experimental capacity curves and the identification of ductility and behaviour (q-factor) parameters. In addition to tests on the unstrengthened configuration (reference configuration), the experimental program also investigates the effectiveness of local strengthening details applied to the beam-to-upright connections, with the goal of increasing frame stiffness and displacement capacity. The experimental results provide a basis for a qualitative and comparative discussion of the influence of the strengthening solutions on global capacity, ductility, and system stability, highlighting critical aspects related to connection response and second-order effects.| File | Dimensione | Formato | |
|---|---|---|---|
|
978-3-032-39505-4_29.pdf
Accesso chiuso
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
3.39 MB
Formato
Adobe PDF
|
3.39 MB | Adobe PDF | Richiedi una copia all'autore |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.