In this investigation we have evaluated the feasibility of using the polymerase chain reaction (PCR) for hepatitis delta virus (HDV) RNA detection, cloning and sequencing. Total RNA from HDV-infected liver and serum samples was purified and Moloney murine leukaemia virus (M-MLV) reverse transcribed. HDV cDNA was then directly amplified with Taq polymerase using three pairs of specific primers. It was possible to amplify a region of about 1200 bp in three partially overlapping fragments including the whole HDAg-ORF. A DNA fragment of the expected size was repeatedly obtained from an initial sample of less than 0.1 pg of liver RNA and from 10 pl of infected serum. An amplified fragment of 359 bp obtained by PCR from an infected woodchucks' liver was sequenced. The sequence was 91.8% and 98.6% identical to previously published HDV sequences. In addition, amplified and 32P-radiolabelled HDV sequences were shown to hybridize specifically to HDV RNA extracted from HDV-infected liver and serum. In conclusion this technique promises to be of great value in the appraisal of HDV infection, rapid synthesis of HDV probes and analysis of the genetic variability of the virus.
Amplification of hepatitis delta virus RNA sequences by polymerase chain reaction: a tool for viral detection and cloning / A.L. Zignego; P. Deny; C. Feray; A. Ponzetto; P. Gentilini; P. Tiollais; C. Brechot. - In: MOLECULAR AND CELLULAR PROBES. - ISSN 0890-8508. - STAMPA. - 4:(1990), pp. 43-51.
Amplification of hepatitis delta virus RNA sequences by polymerase chain reaction: a tool for viral detection and cloning
ZIGNEGO, ANNA LINDA;GENTILINI, PAOLO;
1990
Abstract
In this investigation we have evaluated the feasibility of using the polymerase chain reaction (PCR) for hepatitis delta virus (HDV) RNA detection, cloning and sequencing. Total RNA from HDV-infected liver and serum samples was purified and Moloney murine leukaemia virus (M-MLV) reverse transcribed. HDV cDNA was then directly amplified with Taq polymerase using three pairs of specific primers. It was possible to amplify a region of about 1200 bp in three partially overlapping fragments including the whole HDAg-ORF. A DNA fragment of the expected size was repeatedly obtained from an initial sample of less than 0.1 pg of liver RNA and from 10 pl of infected serum. An amplified fragment of 359 bp obtained by PCR from an infected woodchucks' liver was sequenced. The sequence was 91.8% and 98.6% identical to previously published HDV sequences. In addition, amplified and 32P-radiolabelled HDV sequences were shown to hybridize specifically to HDV RNA extracted from HDV-infected liver and serum. In conclusion this technique promises to be of great value in the appraisal of HDV infection, rapid synthesis of HDV probes and analysis of the genetic variability of the virus.File | Dimensione | Formato | |
---|---|---|---|
1990-Zignego et al MOL CELL PROB.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
836.56 kB
Formato
Adobe PDF
|
836.56 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.