Abstract Relaxed expiratory volume-time profile has been frequently analysed by fitting exponential functions of time to one- or two-compartment models. In the latter case, the two exponential constants are assumed as representing the time constants of both compartments. Least-square fittings on the experimental data of five consecutive mechanically ventilated supine patients with acute respiratory distress syndrome (ARDS) were performed using rate-constants (flow/volume ratio) as parameters in order to obtain the model matching. Passive expiratory volume-time curves were recorded under PEEP = 0 and 13.6 +/- 3.3 S.D. cmH2O conditions. Model matching was optimal with significant, reliable parameter values. As a result, the use of a PEEP in ARDS patients: (a) delayed expiration; (b) decreased the percentage initial volume contribution of the slow-emptying compartment; and, (c) modified the interaction between compartments. The volume-time profile of the second compartment was found to increase at the beginning of expiration, and, then, progressively decayed towards zero, showing a maximum, although the overall curve decreased throughout expiration.

On the interaction between respiratory compartments during passive expiration in ARDS patients / G.L. CHELUCCI ; F. LOCCHI; ZIN WA. - In: RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY. - ISSN 1569-9048. - STAMPA. - 145:(2005), pp. 53-63.

On the interaction between respiratory compartments during passive expiration in ARDS patients

CHELUCCI, GIAN LUCA;LOCCHI, FABRIZIO;
2005

Abstract

Abstract Relaxed expiratory volume-time profile has been frequently analysed by fitting exponential functions of time to one- or two-compartment models. In the latter case, the two exponential constants are assumed as representing the time constants of both compartments. Least-square fittings on the experimental data of five consecutive mechanically ventilated supine patients with acute respiratory distress syndrome (ARDS) were performed using rate-constants (flow/volume ratio) as parameters in order to obtain the model matching. Passive expiratory volume-time curves were recorded under PEEP = 0 and 13.6 +/- 3.3 S.D. cmH2O conditions. Model matching was optimal with significant, reliable parameter values. As a result, the use of a PEEP in ARDS patients: (a) delayed expiration; (b) decreased the percentage initial volume contribution of the slow-emptying compartment; and, (c) modified the interaction between compartments. The volume-time profile of the second compartment was found to increase at the beginning of expiration, and, then, progressively decayed towards zero, showing a maximum, although the overall curve decreased throughout expiration.
2005
145
53
63
G.L. CHELUCCI ; F. LOCCHI; ZIN WA
File in questo prodotto:
File Dimensione Formato  
Chelucci GL et al RPN 2005.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 208 kB
Formato Adobe PDF
208 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/253229
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact