The goal of this work was to compare the behaviour of a chemical vapour deposited (CVD) diamond sample, grown at the University of Florence using a local procedure, with that of a commercial CVD diamond. The comparison was performed exposing both systems to 25 MV photons and measuring the current response during irradiation. Properties of dosimetric interest such as stability of response, dose rate dependence and rise time were investigated. After a preliminary study, which evidenced better performances of the commercial device with respect to the local CVD diamond, the latter was irradiated with a high fluence of fast neutrons. As a result of the neutron treatment, the quality of the CVD home-made diamond has been improved to match with that of the commercial dosemeter.

IMPROVEMENTS IN CVD DIAMOND PROPERTIES FOR RADIOTHERAPY DOSIMETRY / C. DE ANGELIS; M. BUCCIOLINI; M. CASATI; I. LOVIK; M. BRUZZI; S. LAGOMARSINO; S. SCIORTINO; S. ONORI. - In: RADIATION PROTECTION DOSIMETRY. - ISSN 0144-8420. - STAMPA. - 120:(2006), pp. 38-42. [10.1093/rpd/nci508]

IMPROVEMENTS IN CVD DIAMOND PROPERTIES FOR RADIOTHERAPY DOSIMETRY

BUCCIOLINI, MARTA;BRUZZI, MARA;LAGOMARSINO, STEFANO;SCIORTINO, SILVIO;
2006

Abstract

The goal of this work was to compare the behaviour of a chemical vapour deposited (CVD) diamond sample, grown at the University of Florence using a local procedure, with that of a commercial CVD diamond. The comparison was performed exposing both systems to 25 MV photons and measuring the current response during irradiation. Properties of dosimetric interest such as stability of response, dose rate dependence and rise time were investigated. After a preliminary study, which evidenced better performances of the commercial device with respect to the local CVD diamond, the latter was irradiated with a high fluence of fast neutrons. As a result of the neutron treatment, the quality of the CVD home-made diamond has been improved to match with that of the commercial dosemeter.
2006
120
38
42
C. DE ANGELIS; M. BUCCIOLINI; M. CASATI; I. LOVIK; M. BRUZZI; S. LAGOMARSINO; S. SCIORTINO; S. ONORI
File in questo prodotto:
File Dimensione Formato  
Radiat Prot Dosimetry-2006-De Angelis-38-42.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 194.64 kB
Formato Adobe PDF
194.64 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/26955
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16
social impact