OBJECTIVES: The aim of this study was to noninvasively define the hemodynamic profile characterizing the early response to tilting. BACKGROUND: The mechanisms causing orthostatic intolerance have not been fully elucidated. Usually, patients undergoing tilt test are studied in a time-consuming way. Moreover, the test can cause discomfort to the patient and even be potentially hazardous. METHODS: Nineteen orthostatic intolerant patients (OIP), compared with 22 healthy subjects (HS), performed head-up tilt test while their arterial pressure waveform was noninvasively recorded. We elaborated data using the Pressure Recording Analytical Method to obtain hemodynamic parameters, then analyzing the variables by discriminant analysis. RESULTS: Compared with HS, OIP showed lower stroke volume index (SVI) values even in baseline conditions associated with higher values of systemic vascular resistance (SVR) and heart rate (HR). From the third minute of the tilted position and until symptoms appeared, patients exhibited lower values of blood pressure (BP) and SVI and higher HR values but no difference in SVR. At termination, patients showed a further significant reduction in BP and SVI and a persistent increase in HR. CONCLUSIONS: This investigation underlines: 1) the possibility of beat-to-beat monitoring of hemodynamic changes during tilting; 2) the cardiovascular profile of OIP at rest, characterized by lower SVI and higher SVR and HR; 3) the maladaptive response to postural challenge of OIP mainly identifiable in impaired vascular regulation; and 4) the possibility of detecting parameters that enable prompt identification of the positive response to tilting in these patients, thus guiding the duration of the test.
Beat-to-beat analysis of pressure wave morphology for pre-symptomatic detection of orthostatic intolerance during head-up tilt / S. ROMANO; C. LAZZERI; M. CHIOSTRI; G. GENSINI; F. FRANCHI. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - STAMPA. - 44:(2004), pp. 1891-1897.
Beat-to-beat analysis of pressure wave morphology for pre-symptomatic detection of orthostatic intolerance during head-up tilt.
ROMANO, SALVATORE;GENSINI, GIAN FRANCO;FRANCHI, FRANCO
2004
Abstract
OBJECTIVES: The aim of this study was to noninvasively define the hemodynamic profile characterizing the early response to tilting. BACKGROUND: The mechanisms causing orthostatic intolerance have not been fully elucidated. Usually, patients undergoing tilt test are studied in a time-consuming way. Moreover, the test can cause discomfort to the patient and even be potentially hazardous. METHODS: Nineteen orthostatic intolerant patients (OIP), compared with 22 healthy subjects (HS), performed head-up tilt test while their arterial pressure waveform was noninvasively recorded. We elaborated data using the Pressure Recording Analytical Method to obtain hemodynamic parameters, then analyzing the variables by discriminant analysis. RESULTS: Compared with HS, OIP showed lower stroke volume index (SVI) values even in baseline conditions associated with higher values of systemic vascular resistance (SVR) and heart rate (HR). From the third minute of the tilted position and until symptoms appeared, patients exhibited lower values of blood pressure (BP) and SVI and higher HR values but no difference in SVR. At termination, patients showed a further significant reduction in BP and SVI and a persistent increase in HR. CONCLUSIONS: This investigation underlines: 1) the possibility of beat-to-beat monitoring of hemodynamic changes during tilting; 2) the cardiovascular profile of OIP at rest, characterized by lower SVI and higher SVR and HR; 3) the maladaptive response to postural challenge of OIP mainly identifiable in impaired vascular regulation; and 4) the possibility of detecting parameters that enable prompt identification of the positive response to tilting in these patients, thus guiding the duration of the test.File | Dimensione | Formato | |
---|---|---|---|
Jacc.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
184.34 kB
Formato
Adobe PDF
|
184.34 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.