Actually acoustic performance of building components are analyzed with reference to standardized conditions, in laboratories with suppressed flanking transmission. Laboratory results still often show values of the performances quite different from those measured in real buildings, as a consequence of flanking transmission and/or of different conditions of realization in situ. Moreover, in spite of all efforts aimed to standardize laboratory test conditions, it’s quite easy to find different certified performances of same building components obtained in otherwise laboratory. In some cases, these differences may be very relevant. Besides, the Italian decree on acoustic requirement of buildings prescribes limiting values to be measured in situ. For these reasons, many producers of building materials and components more frequently present in their depliants both laboratory values and in situ values of acoustic performances of their products. The paper shows the preliminary results of an research aimed to verify acoustic performances of partition walls and floors in a laboratory which respect conditions of ISO 140-1, but with the presence of relevant flanking transmission, similar to stock buildings. The relevance of the flanking transmission has also analyzed by means of a lining applied to the ceiling of the receiving room of the laboratory.

Influence of flanking transmission in typical Italian constructions / G. Cellai; E. Nannipieri; S. Secchi. - ELETTRONICO. - (2008), pp. 6031-6036. (Intervento presentato al convegno 7th European Conference on Noise Control 2008, EURONOISE 2008 tenutosi a Paris nel Luglio 2008).

Influence of flanking transmission in typical Italian constructions

CELLAI, GIANFRANCO;NANNIPIERI, ELISA;SECCHI, SIMONE
2008

Abstract

Actually acoustic performance of building components are analyzed with reference to standardized conditions, in laboratories with suppressed flanking transmission. Laboratory results still often show values of the performances quite different from those measured in real buildings, as a consequence of flanking transmission and/or of different conditions of realization in situ. Moreover, in spite of all efforts aimed to standardize laboratory test conditions, it’s quite easy to find different certified performances of same building components obtained in otherwise laboratory. In some cases, these differences may be very relevant. Besides, the Italian decree on acoustic requirement of buildings prescribes limiting values to be measured in situ. For these reasons, many producers of building materials and components more frequently present in their depliants both laboratory values and in situ values of acoustic performances of their products. The paper shows the preliminary results of an research aimed to verify acoustic performances of partition walls and floors in a laboratory which respect conditions of ISO 140-1, but with the presence of relevant flanking transmission, similar to stock buildings. The relevance of the flanking transmission has also analyzed by means of a lining applied to the ceiling of the receiving room of the laboratory.
2008
7th European Conference on Noise Control 2008, EURONOISE 2008
7th European Conference on Noise Control 2008, EURONOISE 2008
Paris
Luglio 2008
G. Cellai; E. Nannipieri; S. Secchi
File in questo prodotto:
File Dimensione Formato  
acosutics2008_finale.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Open Access
Dimensione 164.64 kB
Formato Adobe PDF
164.64 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/320913
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact