BACKGROUND: To define the best strategy to reduce Compound A production in Sevoflurane low-flow anaesthesia by experiments in vitro and in vivo of different absorbers and different anaesthesia machines. METHODS: In vitro Compound A has been measured at 45 degrees C in vitro following Sevoflurane interactions with potassium hydroxide, sodium hydroxide, soda lime, Dragersorb 800 Plus and Amsorb, a new absorber that does not contain sodium or potassium hydroxide. In vivo Compound A concentration in the anaesthesia circuit (inspiratory branch) has been measured using an indirect sampling method through absorber vials (SKC) with active coal granules, during low flows (500 ml/min) general anaesthesia using soda lime, Dragersorb 800 Plus or Amsorb as absorber. Compound A was also measured during low flows (500 ml/min) general anaesthesia using as carbon dioxide absorber soda lime with different anaesthesia machines. RESULTS: In vitro at 45 degrees C Compound A concentration with soda lime and Dragersorb 800 Plus was about 10 times higher than with Amsorb. In vivo the Compound A concentrations in the inspiratory branch of the circuit were lower in the group with Amsorb. CONCLUSION: The Compound A production is minimal with Amsorb as carbon dioxide absorber.
SEVOFLURANE LOW-FLOW ANAESTHESIA: BEST STRATEGY TO REDUCE COMPOUND A CONCENTRATION / A.Di Filippo;F.Marini;M.PACENTI;S.DUGHERI;L.FOCARDI;G.P.NOVELLI. - In: ACTA ANAESTHESIOLOGICA SCANDINAVICA. - ISSN 1399-6576. - STAMPA. - 46:(2002), pp. 1017-1020.
SEVOFLURANE LOW-FLOW ANAESTHESIA: BEST STRATEGY TO REDUCE COMPOUND A CONCENTRATION
DI FILIPPO, ALESSANDRO;NOVELLI, GIAN PAOLO
2002
Abstract
BACKGROUND: To define the best strategy to reduce Compound A production in Sevoflurane low-flow anaesthesia by experiments in vitro and in vivo of different absorbers and different anaesthesia machines. METHODS: In vitro Compound A has been measured at 45 degrees C in vitro following Sevoflurane interactions with potassium hydroxide, sodium hydroxide, soda lime, Dragersorb 800 Plus and Amsorb, a new absorber that does not contain sodium or potassium hydroxide. In vivo Compound A concentration in the anaesthesia circuit (inspiratory branch) has been measured using an indirect sampling method through absorber vials (SKC) with active coal granules, during low flows (500 ml/min) general anaesthesia using soda lime, Dragersorb 800 Plus or Amsorb as absorber. Compound A was also measured during low flows (500 ml/min) general anaesthesia using as carbon dioxide absorber soda lime with different anaesthesia machines. RESULTS: In vitro at 45 degrees C Compound A concentration with soda lime and Dragersorb 800 Plus was about 10 times higher than with Amsorb. In vivo the Compound A concentrations in the inspiratory branch of the circuit were lower in the group with Amsorb. CONCLUSION: The Compound A production is minimal with Amsorb as carbon dioxide absorber.File | Dimensione | Formato | |
---|---|---|---|
di filippo sevo 2002.pdf
accesso aperto
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Open Access
Dimensione
49.11 kB
Formato
Adobe PDF
|
49.11 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.