Abstract: The accuracy and reproducibility of a new automatic device (P) specially designed for noninvasive blood pressure monitoring during the exercise stress test were evaluated in 50 consecutive subjects (34 normotensives and 16 hypertensives). Automatic measurements were compared with those taken by a sphygmomanometer (RR). A good agreement between systolic pressure values obtained by the two methods was found (RR 159+/-30 mmHg, P 158+/-28 mmHg, mean difference = -1.53+/-13 mmHg, p = 0. 166, ns). On the contrary the new device significantly underestimated diastolic pressure values (RR 89.3+/-13 mmHg; P 84+/-13 mmHg, mean difference -5.37+/-9.3, p < 0.001). In conclusion the new device seems able to measure systolic but underestimates diastolic blood pressure both in hypertensives and in normotensives during the effort test.

Automated blood pressure determination during exercise test. Clinical evaluation of a new automated device / PA.Modesti; N.Carrabba; GF.Gensini; F.Bonechi; T.Taddei; PL.Malfanti. - In: ANGIOLOGY. - ISSN 0003-3197. - STAMPA. - 43:(1992), pp. 980-987. [10.1177/000331979204301204]

Automated blood pressure determination during exercise test. Clinical evaluation of a new automated device

MODESTI, PIETRO AMEDEO;GENSINI, GIAN FRANCO;
1992

Abstract

Abstract: The accuracy and reproducibility of a new automatic device (P) specially designed for noninvasive blood pressure monitoring during the exercise stress test were evaluated in 50 consecutive subjects (34 normotensives and 16 hypertensives). Automatic measurements were compared with those taken by a sphygmomanometer (RR). A good agreement between systolic pressure values obtained by the two methods was found (RR 159+/-30 mmHg, P 158+/-28 mmHg, mean difference = -1.53+/-13 mmHg, p = 0. 166, ns). On the contrary the new device significantly underestimated diastolic pressure values (RR 89.3+/-13 mmHg; P 84+/-13 mmHg, mean difference -5.37+/-9.3, p < 0.001). In conclusion the new device seems able to measure systolic but underestimates diastolic blood pressure both in hypertensives and in normotensives during the effort test.
1992
43
980
987
PA.Modesti; N.Carrabba; GF.Gensini; F.Bonechi; T.Taddei; PL.Malfanti
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/331145
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact