The purpose of this paper is to present a new device for multimodal head study registration and to examine its performance in preliminary tests. The device consists of a system of eight markers fixed to mobile carbon pipes and bars which can be easily mounted on the patient's head using the ear canals and the nasal bridge. Four graduated scales fixed to the rigid support allow examiners to find the same device position on the patient's head during different acquisitions. The markers can be filled with appropriate substances for visualisation in computed tomography (CT), magnetic resonance, single photon emission computer tomography (SPECT) and positron emission tomography images. The device's rigidity and its position reproducibility were measured in 15 repeated CT acquisitions of the Alderson Rando anthropomorphic phantom and in two SPECT studies of a patient. The proposed system displays good rigidity and reproducibility characteristics. A relocation accuracy of less than 1,5 mm was found in more than 90% of the results. The registration parameters obtained using such a device were compared to those obtained using fiducial markers fixed on phantom and patient heads, resulting in differences of less than V and I mm for rotation and translation parameters, respectively. Residual differences between fiducial marker coordinates in reference and in registered studies were less than 1 mm in more than 90% of the results, proving that the device performed as accurately as noninvasive stereotactic devices. Finally, an example of multimodal employment of the proposed device is reported. (c) 2007 American Association of Physicists in Medicine.
A simple device for high-precision head image registration: Preliminary performance and accuracy tests / S. Pallotta. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - ELETTRONICO. - 34:(2007), pp. 1565-1572. [10.1118/1.2717412]
A simple device for high-precision head image registration: Preliminary performance and accuracy tests
PALLOTTA, STEFANIA
2007
Abstract
The purpose of this paper is to present a new device for multimodal head study registration and to examine its performance in preliminary tests. The device consists of a system of eight markers fixed to mobile carbon pipes and bars which can be easily mounted on the patient's head using the ear canals and the nasal bridge. Four graduated scales fixed to the rigid support allow examiners to find the same device position on the patient's head during different acquisitions. The markers can be filled with appropriate substances for visualisation in computed tomography (CT), magnetic resonance, single photon emission computer tomography (SPECT) and positron emission tomography images. The device's rigidity and its position reproducibility were measured in 15 repeated CT acquisitions of the Alderson Rando anthropomorphic phantom and in two SPECT studies of a patient. The proposed system displays good rigidity and reproducibility characteristics. A relocation accuracy of less than 1,5 mm was found in more than 90% of the results. The registration parameters obtained using such a device were compared to those obtained using fiducial markers fixed on phantom and patient heads, resulting in differences of less than V and I mm for rotation and translation parameters, respectively. Residual differences between fiducial marker coordinates in reference and in registered studies were less than 1 mm in more than 90% of the results, proving that the device performed as accurately as noninvasive stereotactic devices. Finally, an example of multimodal employment of the proposed device is reported. (c) 2007 American Association of Physicists in Medicine.File | Dimensione | Formato | |
---|---|---|---|
A simple device for high-precision head image registration.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
588.84 kB
Formato
Adobe PDF
|
588.84 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.