The design and the first stage of construction of a reinforced concrete public building in Florence, seismically protected by a combined base isolation/supplemental damping system, where silicone-fluid viscous spring-dampers are coupled with steel-Teflon sliding bearings, are presented in the paper.
Application of a combined base isolation/supplemental damping seismic protection strategy to a public building in Florence / S. Sorace; G. Terenzi. - STAMPA. - (2005), pp. 481-486. ( International Conference "250th Anniversary of the 1755 Lisbon Earthquake" Lisbon, Portugal 1-4 November 2005).
Application of a combined base isolation/supplemental damping seismic protection strategy to a public building in Florence
TERENZI, GLORIA
2005
Abstract
The design and the first stage of construction of a reinforced concrete public building in Florence, seismically protected by a combined base isolation/supplemental damping system, where silicone-fluid viscous spring-dampers are coupled with steel-Teflon sliding bearings, are presented in the paper.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



