Proton therapy is a precise forms of radiation therapy that makes use of high energy proton compared to the conventional, more commonly used and less precise x-ray and electron beams. On the other hand, to fully exploit the proton therapy advantages, very accurate quality controls of the treatments are required. These are mainly related to the dose calculations and treatment planning. Actually dose calculations are routinely performed on the basis of X-Ray computed tomography while a big improvement could be obtained with the direct use of protons as the imaging system. In this work we report the results of Monte Carlo simulations for the study of an imaging system based on the use of high energy protons: the proton Computed Tomography (pCT). The main limitation of the pCT and the current adopted technical solutions, based on the use of the Most Likely Path (MLP) approximation are illustrated. Simulation results are compared with experimental data obtained with a first prototype of pCT system tested with 200 MeV proton beams available at the Loma Linda University Medical Center (LLUMC) (CA).

Monte Carlo Studies of a Proton Computed Tomography System / G.Cirrone; G.Cuttone; G.Candiano; F.DiRosa; S.LoNigro; D.Lo Presti; N.Randazzo; V.Sipala; M.Bruzzi; D.Menichelli; M.Scaringella; M.Bashkirov; V.Williams; H.Sadrozinski; J.Heimann; J.Feldt; N.Blumenkrantz; C.Talamonti; R.Schulte. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - ELETTRONICO. - 54:(2007), pp. 1487-1491.

Monte Carlo Studies of a Proton Computed Tomography System

BRUZZI, MARA;MENICHELLI, DAVID;TALAMONTI, CINZIA;
2007

Abstract

Proton therapy is a precise forms of radiation therapy that makes use of high energy proton compared to the conventional, more commonly used and less precise x-ray and electron beams. On the other hand, to fully exploit the proton therapy advantages, very accurate quality controls of the treatments are required. These are mainly related to the dose calculations and treatment planning. Actually dose calculations are routinely performed on the basis of X-Ray computed tomography while a big improvement could be obtained with the direct use of protons as the imaging system. In this work we report the results of Monte Carlo simulations for the study of an imaging system based on the use of high energy protons: the proton Computed Tomography (pCT). The main limitation of the pCT and the current adopted technical solutions, based on the use of the Most Likely Path (MLP) approximation are illustrated. Simulation results are compared with experimental data obtained with a first prototype of pCT system tested with 200 MeV proton beams available at the Loma Linda University Medical Center (LLUMC) (CA).
2007
54
1487
1491
G.Cirrone; G.Cuttone; G.Candiano; F.DiRosa; S.LoNigro; D.Lo Presti; N.Randazzo; V.Sipala; M.Bruzzi; D.Menichelli; M.Scaringella; M.Bashkirov; V.Willia...espandi
File in questo prodotto:
File Dimensione Formato  
04346696-1.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 430.25 kB
Formato Adobe PDF
430.25 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/346431
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 19
social impact