Abstract BACKGROUND: To ascertain if analysis of lung density histograms in thin-section CT was more reproducible than visual assessment of lung changes in systemic sclerosis (SSc), and if such density histogram parameters as mean lung attenuation (MLA), skewness, and kurtosis could more closely reflect pulmonary function as well as exercise and quality of life impairment. METHODS: The intraoperator and interoperator reproducibility of visual and densitometric lung CT analysis in 48 SSc patients examined with CT were evaluated by means of weighted kappa statistics. Univariate and multivariate regression analyses were applied to evaluate the relationship of visual and densitometric CT measurements with functional parameters including functional residual capacity (FRC), FVC, FEV(1), diffusion capacity of the lung for carbon monoxide (Dlco), 6-min walking testing (6MWT), and health-related quality of life questionnaire (QLQ) parameters. RESULTS: The intraoperator and interoperator reproducibility of MLA (intraobserver weighted kappa = 0.97; interobserver weighted kappa = 0.96), skewness (intraobserver weighted kappa = 0.89; interobserver weighted kappa = 0.88), and kurtosis (intraobserver weighted kappa = 0.89; interobserver weighted kappa = 0.88) were higher than those of visual assessment (intraobserver weighted kappa = 0.71; interobserver weighted kappa = 0.69). In univariate analysis, only densitometric measurements were correlated with some exercise and QLQ parameters. In multivariate analysis, MLA (square regression coefficient corrected [R(2)c] = 0.70), skewness (R(2)c = 0.78), and kurtosis (R(2)c = 0.77) were predicted by FRC, FVC, Dlco, 6MWT, and QLQ parameters, while visual assessment was associated only with FRC and FVC (R(2)c = 0.40). CONCLUSIONS: In SSc, densitometric analysis is more reproducible than visual assessment of lung changes in thin-section CT and more closely correlated to pulmonary function testing, 6MWT, and QLQ. Density histogram parameters may be useful for cross-sectional and longitudinal studies of lung involvement in SSc.

Lung CT densitometry in systemic sclerosis: correlation with lung function, exercise testing, and quality of life / Camiciottoli G; Orlandi I; Bartolucci M; Meoni E; Nacci F; Diciotti S; Barcaroli C; Conforti ML; Pistolesi M; Matucci-Cerinic M; Mascalchi M.. - In: CHEST. - ISSN 0012-3692. - STAMPA. - 131:(2007), pp. 672-681. [10.1378/chest.06-1401]

Lung CT densitometry in systemic sclerosis: correlation with lung function, exercise testing, and quality of life

CAMICIOTTOLI, GIANNA;MEONI, ELEONORA;DICIOTTI, STEFANO;BARCAROLI, CHIARA;PISTOLESI, MASSIMO;Matucci Cerinic M;MASCALCHI, MARIO
2007

Abstract

Abstract BACKGROUND: To ascertain if analysis of lung density histograms in thin-section CT was more reproducible than visual assessment of lung changes in systemic sclerosis (SSc), and if such density histogram parameters as mean lung attenuation (MLA), skewness, and kurtosis could more closely reflect pulmonary function as well as exercise and quality of life impairment. METHODS: The intraoperator and interoperator reproducibility of visual and densitometric lung CT analysis in 48 SSc patients examined with CT were evaluated by means of weighted kappa statistics. Univariate and multivariate regression analyses were applied to evaluate the relationship of visual and densitometric CT measurements with functional parameters including functional residual capacity (FRC), FVC, FEV(1), diffusion capacity of the lung for carbon monoxide (Dlco), 6-min walking testing (6MWT), and health-related quality of life questionnaire (QLQ) parameters. RESULTS: The intraoperator and interoperator reproducibility of MLA (intraobserver weighted kappa = 0.97; interobserver weighted kappa = 0.96), skewness (intraobserver weighted kappa = 0.89; interobserver weighted kappa = 0.88), and kurtosis (intraobserver weighted kappa = 0.89; interobserver weighted kappa = 0.88) were higher than those of visual assessment (intraobserver weighted kappa = 0.71; interobserver weighted kappa = 0.69). In univariate analysis, only densitometric measurements were correlated with some exercise and QLQ parameters. In multivariate analysis, MLA (square regression coefficient corrected [R(2)c] = 0.70), skewness (R(2)c = 0.78), and kurtosis (R(2)c = 0.77) were predicted by FRC, FVC, Dlco, 6MWT, and QLQ parameters, while visual assessment was associated only with FRC and FVC (R(2)c = 0.40). CONCLUSIONS: In SSc, densitometric analysis is more reproducible than visual assessment of lung changes in thin-section CT and more closely correlated to pulmonary function testing, 6MWT, and QLQ. Density histogram parameters may be useful for cross-sectional and longitudinal studies of lung involvement in SSc.
2007
131
672
681
Camiciottoli G; Orlandi I; Bartolucci M; Meoni E; Nacci F; Diciotti S; Barcaroli C; Conforti ML; Pistolesi M; Matucci-Cerinic M; Mascalchi M.
File in questo prodotto:
File Dimensione Formato  
Camiciottoli et al Chest 2007.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 652.28 kB
Formato Adobe PDF
652.28 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/350691
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 99
  • ???jsp.display-item.citation.isi??? 90
social impact