Fiber-reinforced polymer (FRP) composites are more and more used in the building trade for the set up of reinforcing and repair devices. As known, FRP composites offer higher strength and Young modulus than traditional steel devices, but nowadays technologies are not able to produce pretension of the wrap in civil engineering strengthening applications. Moreover, when confining compressed masonry columns with FRP composites, the effective contribution of the composite cannot be accurately evaluated. In the present paper, some theoretical relationships available in literature are analyzed, regarding the evaluation of confinement effect on wrapped masonry columns. The reliability of these formulations is investigated, comparing the theoretical values with unixial and triaxial experimental test results; unixial tests were carried out both on plain and wrapped brick masonry samples. Experimental results are shown not to fit to the formulas of the literature and the reasons of the discrepancy were searched for in the mechanical process that produces failure.

Study of brick masonry columns confined with CFRP composite / V. Alecci; S. Briccoli Bati; G. Ranocchiai. - In: JOURNAL OF COMPOSITES FOR CONSTRUCTION. - ISSN 1090-0268. - STAMPA. - Vol. 13, n. 3:(2009), pp. 179-187. [10.1061/(ASCE)1090-0268(2009)13:3(179)]

Study of brick masonry columns confined with CFRP composite

ALECCI, VALERIO;BRICCOLI BATI, SILVIA;RANOCCHIAI, GIOVANNA
2009

Abstract

Fiber-reinforced polymer (FRP) composites are more and more used in the building trade for the set up of reinforcing and repair devices. As known, FRP composites offer higher strength and Young modulus than traditional steel devices, but nowadays technologies are not able to produce pretension of the wrap in civil engineering strengthening applications. Moreover, when confining compressed masonry columns with FRP composites, the effective contribution of the composite cannot be accurately evaluated. In the present paper, some theoretical relationships available in literature are analyzed, regarding the evaluation of confinement effect on wrapped masonry columns. The reliability of these formulations is investigated, comparing the theoretical values with unixial and triaxial experimental test results; unixial tests were carried out both on plain and wrapped brick masonry samples. Experimental results are shown not to fit to the formulas of the literature and the reasons of the discrepancy were searched for in the mechanical process that produces failure.
2009
Vol. 13, n. 3
179
187
V. Alecci; S. Briccoli Bati; G. Ranocchiai
File in questo prodotto:
File Dimensione Formato  
Studi of brick masonry columns ASCE.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 319.74 kB
Formato Adobe PDF
319.74 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/359809
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 29
social impact