The development of a cyclodextrin-MEEKC method for the analysis of oxybutynin and five related impurities is described. Experimental design strategies were applied in order to reach baseline separation of the compounds in a short analysis time. Mixture design made it possible to find the best composition for the microemulsion acting as pseudostationary phase, which was constituted by 89.1% 10mM borate buffer pH 9.2, 1.7% n-heptane, 9.2% SDS/n-butanol in 1:2 ratio. The addition of (2-hydroxypropyl)- _-cyclodextrin to the background electrolyte was found to improve analysis performance. A Doehlert design, for the factors cyclodextrin concentration and voltage, was carried out and Derringer desirability function led to the identification of 18mM and 29 kV as the optimal values. Applying the optimum conditions, separation of all the compounds, including the enantiomers of impurity 1, was obtained in less than 12 min. The method was validated according to ICH guidelines for drug assay and determination of impurities and was applied to oxybutynin tablet analysis.

Cyclodextrin-MEEKC for the analysis of oxybutynin and its impurities / I.Giannini; S.Orlandini; R.Gotti; S.Pinzauti;S.Furlanetto. - In: TALANTA. - ISSN 0039-9140. - STAMPA. - 80:(2009), pp. 781-788. [10.1016/j.talanta.2009.07.071]

Cyclodextrin-MEEKC for the analysis of oxybutynin and its impurities

GIANNINI, IACOPO;ORLANDINI, SERENA;PINZAUTI, SERGIO;FURLANETTO, SANDRA
2009

Abstract

The development of a cyclodextrin-MEEKC method for the analysis of oxybutynin and five related impurities is described. Experimental design strategies were applied in order to reach baseline separation of the compounds in a short analysis time. Mixture design made it possible to find the best composition for the microemulsion acting as pseudostationary phase, which was constituted by 89.1% 10mM borate buffer pH 9.2, 1.7% n-heptane, 9.2% SDS/n-butanol in 1:2 ratio. The addition of (2-hydroxypropyl)- _-cyclodextrin to the background electrolyte was found to improve analysis performance. A Doehlert design, for the factors cyclodextrin concentration and voltage, was carried out and Derringer desirability function led to the identification of 18mM and 29 kV as the optimal values. Applying the optimum conditions, separation of all the compounds, including the enantiomers of impurity 1, was obtained in less than 12 min. The method was validated according to ICH guidelines for drug assay and determination of impurities and was applied to oxybutynin tablet analysis.
2009
80
781
788
I.Giannini; S.Orlandini; R.Gotti; S.Pinzauti;S.Furlanetto
File in questo prodotto:
File Dimensione Formato  
2009_Giannini-I._Talanta.pdf

Accesso chiuso

Tipologia: Altro
Licenza: Tutti i diritti riservati
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/366489
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 27
social impact