Advantages of dried blood spot include low invasiveness, ease and low cost of sample collection, transport, and storage. We used tandem mass spectrometry (LC-MS/MS) to determine phenobarbital levels on dried blood spot specimens and compared this methodology to commercially available particle enhanced turbidimetric inhibition immunoassay (PETINIA) in plasma/serum samples. The calibration curve in matrix using D5-phenobarbital as internal standard was linear in the phenobarbital concentration range of 1–100 mg/L (correlation coefficient 0.9996). The coefficients of variation in blood spots ranged 2.29–6.71% and the accuracy ranged 96.54– 103.87%. There were no significant differences between the concentrations measured using PETINA and LC-MS/MS (both had similar precision and accuracy) however, LC-MS/MS allows at least 1.5 times higher throughput of phenobarbital analysis and additionally offers ease of sample collection which is particularly important for newborns or small infants.
A new rapid micromethod for the assay of phenobarbital from dried blood spots by LC-tandem mass spectrometry / la Marca G; Malvagia S; Filippi L; Luceri F; Moneti G; Guerrini R. - In: EPILEPSIA. - ISSN 0013-9580. - ELETTRONICO. - 50(12):(2009), pp. 2658-2662.
A new rapid micromethod for the assay of phenobarbital from dried blood spots by LC-tandem mass spectrometry
LA MARCA, GIANCARLO;MONETI, GLORIANO;GUERRINI, RENZO
2009
Abstract
Advantages of dried blood spot include low invasiveness, ease and low cost of sample collection, transport, and storage. We used tandem mass spectrometry (LC-MS/MS) to determine phenobarbital levels on dried blood spot specimens and compared this methodology to commercially available particle enhanced turbidimetric inhibition immunoassay (PETINIA) in plasma/serum samples. The calibration curve in matrix using D5-phenobarbital as internal standard was linear in the phenobarbital concentration range of 1–100 mg/L (correlation coefficient 0.9996). The coefficients of variation in blood spots ranged 2.29–6.71% and the accuracy ranged 96.54– 103.87%. There were no significant differences between the concentrations measured using PETINA and LC-MS/MS (both had similar precision and accuracy) however, LC-MS/MS allows at least 1.5 times higher throughput of phenobarbital analysis and additionally offers ease of sample collection which is particularly important for newborns or small infants.File | Dimensione | Formato | |
---|---|---|---|
PB.pdf
accesso aperto
Tipologia:
Altro
Licenza:
Open Access
Dimensione
223.58 kB
Formato
Adobe PDF
|
223.58 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.