Equivalent static loads on buildings are usually evaluated following the quasi-steady approach, assuming that instantaneous approaching wind velocities are directly translated into surface pressures at all points on the building faces. Such an approach is in contrast with the actual nature of pressures, acting on the faces, exposed to a separated flow. For these, mean and fluctuating pressures are not directly related to the characteristics of the oncoming flow and, to an even lesser extent are fully correlated to those acting at corresponding points on the windward surfaces. To investigate the characteristics of the pressure fluctuations on the leeward and side faces of medium-rise, rectangular plan buildings and to quantify the error associated with the quasi-steady assumption, in this paper the results of wind tunnel pressure measurements are discussed. The characteristics of fluctuating pressures and the equivalent static load are compared with those arising from the application of the quasi-steady approach and from the use of codes of practice.

Characterisation of pressure fluctuations on the leeward and side faces of rectangular buildings and accuracy of the quasi-steady loads / G. Bartoli; F. Ricciardelli. - In: JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS. - ISSN 0167-6105. - ELETTRONICO. - 98 (10-11):(2010), pp. 512-519. [10.1016/j.jweia.2010.04.001]

Characterisation of pressure fluctuations on the leeward and side faces of rectangular buildings and accuracy of the quasi-steady loads

BARTOLI, GIANNI;
2010

Abstract

Equivalent static loads on buildings are usually evaluated following the quasi-steady approach, assuming that instantaneous approaching wind velocities are directly translated into surface pressures at all points on the building faces. Such an approach is in contrast with the actual nature of pressures, acting on the faces, exposed to a separated flow. For these, mean and fluctuating pressures are not directly related to the characteristics of the oncoming flow and, to an even lesser extent are fully correlated to those acting at corresponding points on the windward surfaces. To investigate the characteristics of the pressure fluctuations on the leeward and side faces of medium-rise, rectangular plan buildings and to quantify the error associated with the quasi-steady assumption, in this paper the results of wind tunnel pressure measurements are discussed. The characteristics of fluctuating pressures and the equivalent static load are compared with those arising from the application of the quasi-steady approach and from the use of codes of practice.
2010
98 (10-11)
512
519
G. Bartoli; F. Ricciardelli
File in questo prodotto:
File Dimensione Formato  
2010_Bartoli_Ricciardelli.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 704.02 kB
Formato Adobe PDF
704.02 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/395589
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 10
social impact