Eur Heart J. 2009 Dec;30(24):3007-14. Abnormal coronary reserve and left ventricular wall motion during cold pressor test in patients with previous left ventricular ballooning syndrome. Barletta G, Del Pace S, Boddi M, Del Bene R, Salvadori C, Bellandi B, Coppo M, Saletti E, Gensini GF. Non Invasive Cardiology, Department of Heart and Vessels, AOU Careggi, Florence 50134, Italy. barlettagius@tiscali.it AIMS: To investigate whether and how cold pressor test (CPT) could affect myocardial perfusion and left ventricular (LV) function in patients with previous LV ballooning syndrome (LVBS). METHODS AND RESULTS: Cold pressor test (3 min hand immersion in ice-water) was performed in 17 women with previous LVBS and in 7 age- and risk factor-matched women with chest pain and normal coronary arteries. At baseline and peak CPT, global and regional LV function, and myocardial perfusion were quantitatively assessed by real-time three-dimensional echocardiography (RT3DE) and myocardial contrast (SonoVue, Bracco) 2D echocardiography (MCE), respectively (Philips iE33 machine, X3-1 and S5-1 probes). Data were analysed off-line (QLab 6.0 software). Peripheral venous catecholamines were assayed by high performance liquid chromatography with electrochemical detection. Cold pressor test induced similar haemodynamic changes and catecholamine increase in controls and LVBS patients. Left ventricular ejection fraction decreased and transient new mid-ventricular and apical motion abnormalities developed in LVBS patients only (quantitative RT3D analysis), without corresponding perfusion defects (MCE). At peak CPT, coronary blood flow and velocity increased (quantitative MCE analysis) in control subjects only. CONCLUSION: Cold pressor test induced LV wall motion abnormalities unmatched to regional coronary flow reduction in LVBS patients only. The reduced coronary reserve in response to CPT suggests microvascular dysfunction in LVBS patients. PMID: 19700469 [PubMed - indexed for MEDLINE]

Abnormal coronary reserve and left ventricular wall motion during cold pressor test in patients with previous left ventricular ballooning syndrome / Barletta G; Del Pace S; Boddi M; Del Bene R; Salvadori C; Bellandi B; Coppo M; Saletti E; Gensini GF.. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - ELETTRONICO. - 30:(2009), pp. 3007-3014. [10.1093/eurheartj/ehp325]

Abnormal coronary reserve and left ventricular wall motion during cold pressor test in patients with previous left ventricular ballooning syndrome.

BODDI, MARIA;BELLANDI, BENEDETTA;COPPO, MIRELLA;GENSINI, GIAN FRANCO
2009

Abstract

Eur Heart J. 2009 Dec;30(24):3007-14. Abnormal coronary reserve and left ventricular wall motion during cold pressor test in patients with previous left ventricular ballooning syndrome. Barletta G, Del Pace S, Boddi M, Del Bene R, Salvadori C, Bellandi B, Coppo M, Saletti E, Gensini GF. Non Invasive Cardiology, Department of Heart and Vessels, AOU Careggi, Florence 50134, Italy. barlettagius@tiscali.it AIMS: To investigate whether and how cold pressor test (CPT) could affect myocardial perfusion and left ventricular (LV) function in patients with previous LV ballooning syndrome (LVBS). METHODS AND RESULTS: Cold pressor test (3 min hand immersion in ice-water) was performed in 17 women with previous LVBS and in 7 age- and risk factor-matched women with chest pain and normal coronary arteries. At baseline and peak CPT, global and regional LV function, and myocardial perfusion were quantitatively assessed by real-time three-dimensional echocardiography (RT3DE) and myocardial contrast (SonoVue, Bracco) 2D echocardiography (MCE), respectively (Philips iE33 machine, X3-1 and S5-1 probes). Data were analysed off-line (QLab 6.0 software). Peripheral venous catecholamines were assayed by high performance liquid chromatography with electrochemical detection. Cold pressor test induced similar haemodynamic changes and catecholamine increase in controls and LVBS patients. Left ventricular ejection fraction decreased and transient new mid-ventricular and apical motion abnormalities developed in LVBS patients only (quantitative RT3D analysis), without corresponding perfusion defects (MCE). At peak CPT, coronary blood flow and velocity increased (quantitative MCE analysis) in control subjects only. CONCLUSION: Cold pressor test induced LV wall motion abnormalities unmatched to regional coronary flow reduction in LVBS patients only. The reduced coronary reserve in response to CPT suggests microvascular dysfunction in LVBS patients. PMID: 19700469 [PubMed - indexed for MEDLINE]
2009
30
3007
3014
Barletta G; Del Pace S; Boddi M; Del Bene R; Salvadori C; Bellandi B; Coppo M; Saletti E; Gensini GF.
File in questo prodotto:
File Dimensione Formato  
barletta 2009.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 320.19 kB
Formato Adobe PDF
320.19 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/396554
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 30
social impact