A major goal in clinical positron emission tomogra- phy is to measure the radioisotope concentrations with the best spatial resolution possible. In spite of different factors affecting the spatial resolution, in this work we focused on the geometrical system response, and in particular on the problem arising from the interactions of the gamma rays in the detector array. Starting from the single detector response (intrinsic aperture function, IAF), we modeled the absorption of gamma rays on a probabilistic base. Then, in order to obtain the PET response function, we correlated the IAF with the opposite detector response, so obtaining the coincidence aperture function (CAF). It was possible to obtain an analytical expression of the CAF and of its normalization factor for a generic source position inside the field of view. The CAF experimental validations we are performing are giving a good experimental-theoretical matching, so the future step will be the CAF implementation in reconstruction algorithms.

Mathematical-physical characterization of the response function of a clinical PET / A.Passeri; A.Bartoli. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - STAMPA. - 6:(2004), pp. 3831-3834.

Mathematical-physical characterization of the response function of a clinical PET

PASSERI, ALESSANDRO;
2004

Abstract

A major goal in clinical positron emission tomogra- phy is to measure the radioisotope concentrations with the best spatial resolution possible. In spite of different factors affecting the spatial resolution, in this work we focused on the geometrical system response, and in particular on the problem arising from the interactions of the gamma rays in the detector array. Starting from the single detector response (intrinsic aperture function, IAF), we modeled the absorption of gamma rays on a probabilistic base. Then, in order to obtain the PET response function, we correlated the IAF with the opposite detector response, so obtaining the coincidence aperture function (CAF). It was possible to obtain an analytical expression of the CAF and of its normalization factor for a generic source position inside the field of view. The CAF experimental validations we are performing are giving a good experimental-theoretical matching, so the future step will be the CAF implementation in reconstruction algorithms.
2004
6
3831
3834
A.Passeri; A.Bartoli
File in questo prodotto:
File Dimensione Formato  
articolo_2.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 401.82 kB
Formato Adobe PDF
401.82 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/397121
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact