Due to the features of modern radiotherapy techniques, such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic Treatments with photons and proton therapy, where high spatial dose gradient are often present, detectors to be employed for two-dimensional dose verifications must satisfy narrow requirements. In particular, they have to exhibit high spatial resolution. For these applications, in the framework of the European Integrated project MAESTRO (LSHC-CT-2004-503564) and of the INFN experiment PRIMA, we designed a modular system based on a monolithic silicon segmented sensor. A single sensor has been coupled with readout electronics and tested with satisfactory results by using 6, 10 and 25MV X-rays from a LINAC at the University Hospital of Florence and 62MeV protons at INFN LNS Catania, following MAESTRO procedures. For photons, almost all the channels exhibit performances within project specifications (repeatability ≪0.5%, reproducibility ≪1%, deviation from linearity ≪1%, dose rate dependence ≪1%). For protons, the measured Spread Out Bragg Peak is in good agreement with the one measured with a single diode and the detector shows also a good linearity in the range 20–5000 cGy. The output factors are in agreement with those measured with ionization chamber, single diode or film, within experimental errors.

2D Dosimeter Based on Monolithic Silicon Sensors for Beam Verification in Conformal Radiotherapy / Talamonti C ; Bruzzi M ; Bucciolini M ; Marrazzo L ; Menichelli D ; Brianzi M ; Tesi M ; Cirrone GAP ; Cuttone G; LoJacono P ; La Rosa A. - ELETTRONICO. - (2009), pp. 685-690. (Intervento presentato al convegno Nuclear Science Symposium Conference 2008 tenutosi a Dresda, Germania nel 19-25 ottobre 2008) [10.1109/NSSMIC.2008.4774679].

2D Dosimeter Based on Monolithic Silicon Sensors for Beam Verification in Conformal Radiotherapy

TALAMONTI, CINZIA;BRUZZI, MARA;BUCCIOLINI, MARTA;Marrazzo L.;MENICHELLI, DAVID;
2009

Abstract

Due to the features of modern radiotherapy techniques, such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic Treatments with photons and proton therapy, where high spatial dose gradient are often present, detectors to be employed for two-dimensional dose verifications must satisfy narrow requirements. In particular, they have to exhibit high spatial resolution. For these applications, in the framework of the European Integrated project MAESTRO (LSHC-CT-2004-503564) and of the INFN experiment PRIMA, we designed a modular system based on a monolithic silicon segmented sensor. A single sensor has been coupled with readout electronics and tested with satisfactory results by using 6, 10 and 25MV X-rays from a LINAC at the University Hospital of Florence and 62MeV protons at INFN LNS Catania, following MAESTRO procedures. For photons, almost all the channels exhibit performances within project specifications (repeatability ≪0.5%, reproducibility ≪1%, deviation from linearity ≪1%, dose rate dependence ≪1%). For protons, the measured Spread Out Bragg Peak is in good agreement with the one measured with a single diode and the detector shows also a good linearity in the range 20–5000 cGy. The output factors are in agreement with those measured with ionization chamber, single diode or film, within experimental errors.
2009
Proceedings of Nuclear Science Symposium Conference
Nuclear Science Symposium Conference 2008
Dresda, Germania
19-25 ottobre 2008
Talamonti C ; Bruzzi M ; Bucciolini M ; Marrazzo L ; Menichelli D ; Brianzi M ; Tesi M ; Cirrone GAP ; Cuttone G; LoJacono P ; La Rosa A
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/397638
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact