We present a modular rack-mounted laser system for the cooling and manipulation of neutral rubidium atoms which has been developed for a portable gravimeter based on atom interferometry that will be capable of performing high-precision gravity measurements directly at sites of geophysical interest. This laser system is constructed in a compact and mobile design so that it can be transported to different locations, yet it still offers improvements over many conventional laboratory-based laser systems. Our system is contained in a standard 19 rack and emits light at five different frequencies simultaneously on up to 12 fibre ports at a total output power of 800 mW. These frequencies can be changed and switched between ports in less than a microsecond. The setup includes two phase-locked diode lasers with a phase noise spectral density of less than 1 μrad/Hz1/2 in the frequency range in which our gravimeter is most sensitive to noise. We characterise this laser system and evaluate the performance limits it imposes on an interferometer.
A portable laser system for high-precision atom interferometry experiments / M. Schmidt; M. Prevedelli; A. Giorgini; G.M. Tino; A. Peters. - In: APPLIED PHYSICS. B, LASERS AND OPTICS. - ISSN 0946-2171. - STAMPA. - 102:(2011), pp. 11-18. [10.1007/s00340-010-4263-8]
A portable laser system for high-precision atom interferometry experiments
PREVEDELLI, MARCO;TINO, GUGLIELMO MARIA;
2011
Abstract
We present a modular rack-mounted laser system for the cooling and manipulation of neutral rubidium atoms which has been developed for a portable gravimeter based on atom interferometry that will be capable of performing high-precision gravity measurements directly at sites of geophysical interest. This laser system is constructed in a compact and mobile design so that it can be transported to different locations, yet it still offers improvements over many conventional laboratory-based laser systems. Our system is contained in a standard 19 rack and emits light at five different frequencies simultaneously on up to 12 fibre ports at a total output power of 800 mW. These frequencies can be changed and switched between ports in less than a microsecond. The setup includes two phase-locked diode lasers with a phase noise spectral density of less than 1 μrad/Hz1/2 in the frequency range in which our gravimeter is most sensitive to noise. We characterise this laser system and evaluate the performance limits it imposes on an interferometer.File | Dimensione | Formato | |
---|---|---|---|
2011 A portable laser system.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Tutti i diritti riservati
Dimensione
2.06 MB
Formato
Adobe PDF
|
2.06 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.