A detailed investigation of the performance as a dosimeter of state-of-art polycrystalline CVD (pCVD) diamond detectors operated in photovoltaic regime for applications in clinical radiotherapy has been carried out with conventional 6–10–18 MV X-photons, as well as with a 10 MV photon Intensity Modulated Radiation Therapy (IMRT) beam from a linear accelerator. Our results show that the performances of a pCVD diamond dosimeter improves dramatically when operated in null-bias conditions. Main improvements with respect to operation with an external voltage applied are: a reduced pre-irradiation dose; an excellent time stability, characterised by standard deviations less than 0.5%; a rise-time comparable to that of commercial reference dosimeters; a linearity with dose proven over three decades; a reduced deviation from linearity of the current vs. dose–rate curve, output factors comparable to that of commercial reference dosimeters. These results represent a signi!cant step towards clinical applications as IMRT with synthetic polycrystalline CVD diamond films.
Zero-bias operation of polycrystalline chemically vapour deposited diamond films for Intensity Modulated Radiation Therapy / M. Bruzzi; C. DeAngelis; M. Scaringella; C. Talamonti; D. Viscomi; M. Bucciolini. - In: DIAMOND AND RELATED MATERIALS. - ISSN 0925-9635. - STAMPA. - 20:(2011), pp. 84-92. [10.1016/j.diamond.2010.11.011]
Zero-bias operation of polycrystalline chemically vapour deposited diamond films for Intensity Modulated Radiation Therapy
BRUZZI, MARA;SCARINGELLA, MONICA;TALAMONTI, CINZIA;BUCCIOLINI, MARTA
2011
Abstract
A detailed investigation of the performance as a dosimeter of state-of-art polycrystalline CVD (pCVD) diamond detectors operated in photovoltaic regime for applications in clinical radiotherapy has been carried out with conventional 6–10–18 MV X-photons, as well as with a 10 MV photon Intensity Modulated Radiation Therapy (IMRT) beam from a linear accelerator. Our results show that the performances of a pCVD diamond dosimeter improves dramatically when operated in null-bias conditions. Main improvements with respect to operation with an external voltage applied are: a reduced pre-irradiation dose; an excellent time stability, characterised by standard deviations less than 0.5%; a rise-time comparable to that of commercial reference dosimeters; a linearity with dose proven over three decades; a reduced deviation from linearity of the current vs. dose–rate curve, output factors comparable to that of commercial reference dosimeters. These results represent a signi!cant step towards clinical applications as IMRT with synthetic polycrystalline CVD diamond films.File | Dimensione | Formato | |
---|---|---|---|
diamond&relatedmaterials2011.pdf
accesso aperto
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Open Access
Dimensione
861.99 kB
Formato
Adobe PDF
|
861.99 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.