The aim of this study was to quantify on the measurement variation of in vivo load-displacement curves by using a group of human healthy heel pads. The recordings were done with a compression device measuring force and displacement. Twenty three heel pads, one from each of 23 subjects aged 20-35 years, were tested. The load-displacement curves showed the hysteresis, typical for a visco-elastic tissue. Seven load-displacement curves were measured for each subject. Each hysteresis was approximated by a 3rd degree polynomial, which in turn was described by two parameters: the slope and the average curvature. No statistically significant tendency (increasing or decreasing) were found for the seven polynomials (χ2 test, P-values of 0.81 and 0.17 for the two parameters, respectively). The study revealed no systematic error in the recorded load-displacement curves. The mean slope and the average curvature for the 23 subjects were found to be 6.02±1.54 N/mm and 0.02±0.01, respectively. The new apparatus shows its reliability for further clinical investigations.

Initial studies on the variations of load-displacement curves of in vivo human healthy heel pads / S.Matteoli; J.E.Wilhjelm; A.Virga; A.Corvi; S.T.Torp-Perdersen. - STAMPA. - 34:(2011), pp. 152-155. (Intervento presentato al convegno IFMBE tenutosi a Aalborg nel 14-17 giugno 2011) [10.1007/978-3-642-21683-1_38].

Initial studies on the variations of load-displacement curves of in vivo human healthy heel pads

MATTEOLI, SARA;VIRGA, ANTONIO;CORVI, ANDREA;
2011

Abstract

The aim of this study was to quantify on the measurement variation of in vivo load-displacement curves by using a group of human healthy heel pads. The recordings were done with a compression device measuring force and displacement. Twenty three heel pads, one from each of 23 subjects aged 20-35 years, were tested. The load-displacement curves showed the hysteresis, typical for a visco-elastic tissue. Seven load-displacement curves were measured for each subject. Each hysteresis was approximated by a 3rd degree polynomial, which in turn was described by two parameters: the slope and the average curvature. No statistically significant tendency (increasing or decreasing) were found for the seven polynomials (χ2 test, P-values of 0.81 and 0.17 for the two parameters, respectively). The study revealed no systematic error in the recorded load-displacement curves. The mean slope and the average curvature for the 23 subjects were found to be 6.02±1.54 N/mm and 0.02±0.01, respectively. The new apparatus shows its reliability for further clinical investigations.
2011
IFMBE Proceedings
IFMBE
Aalborg
14-17 giugno 2011
S.Matteoli; J.E.Wilhjelm; A.Virga; A.Corvi; S.T.Torp-Perdersen
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/477856
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact