The particulate emissions near a large steel plant located in a densely inhabited suburb of the town of Geneva (Italy) have been studied for a period of six months. We hale used two-stage continuous streaker samplers and subsequent PIXE analysis with hourly resolution, to follow both seasonal and daily trends. The first streaker sampler remained installed very close to the plant cokery and furnaces, while another sampler was moved to different locations. Samples have been analysed by PIXE, deducing concentrations for elements from Na to Pb. During part of the campaign. the aerosol fractions with aerodynamic diameter (D-ae) < 2.5 mu m (fine fraction) and with 2.5 < D-ae < 10 mu m (coarse fraction) have been separately collected. We have measured and analysed about 8500 PIXE spectra: the steel plant emissions have been identified to some extent and resolved from other aerosol sources.

Study of particulate emission near a steel plant in Genova by continous sampling and PIXE hourly analysis / P. Prati; P. Putti; A. Zucchiatti; F. Lucarelli; P.A. Mando'. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - STAMPA. - vol.150:(1999), pp. 428-432. [10.1016/S0168-583X(98)00984-7]

Study of particulate emission near a steel plant in Genova by continous sampling and PIXE hourly analysis

LUCARELLI, FRANCO;MANDO', PIER ANDREA
1999

Abstract

The particulate emissions near a large steel plant located in a densely inhabited suburb of the town of Geneva (Italy) have been studied for a period of six months. We hale used two-stage continuous streaker samplers and subsequent PIXE analysis with hourly resolution, to follow both seasonal and daily trends. The first streaker sampler remained installed very close to the plant cokery and furnaces, while another sampler was moved to different locations. Samples have been analysed by PIXE, deducing concentrations for elements from Na to Pb. During part of the campaign. the aerosol fractions with aerodynamic diameter (D-ae) < 2.5 mu m (fine fraction) and with 2.5 < D-ae < 10 mu m (coarse fraction) have been separately collected. We have measured and analysed about 8500 PIXE spectra: the steel plant emissions have been identified to some extent and resolved from other aerosol sources.
1999
vol.150
428
432
P. Prati; P. Putti; A. Zucchiatti; F. Lucarelli; P.A. Mando'
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/482269
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact