In the silicon tracker for the Compact Muon Solenoid experiment at the forthcoming Large Hadron Collider of CERN, each silicon sensor is connected to the front-end electronics by a pitch adapter, the structure of which consists of a fan of very thin chromium strips coated with a few microns aluminium deposition, on a glass support. The absence of contaminants in the depositions is of crucial importance for the electrical and mechanical reliability of the micro-bonding connections. The PIXE set-up of the Florence external micro-beam facility appeared to be suitable to analyse the metal deposition of an adapter, on which the micro-bonds had shown mechanical and electrical problems. Our measurements pointed out a significant copper contamination of the metal deposition on the faulty adapter, while no copper was detected in another one, which showed a correct behaviour at bonding. This suggests a possible role of Cu impurities in the encountered problems during micro-bonding.
Use of micro-PIXE analysis for the identification of contaminants in the metal deposition on a CMS pitch adapter / M. Massi, L. Giuntini, M.E. Fedi, C. Arilli, N. Grassi, P.A. Mando', A. Migliori, E. Focardi. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - STAMPA. - vol.219-220:(2004), pp. 722-726.
Use of micro-PIXE analysis for the identification of contaminants in the metal deposition on a CMS pitch adapter
MASSI, MIRKO;GIUNTINI, LORENZO;FEDI, MARIAELENA;ARILLI, CHIARA;GRASSI, NOVELLA;MANDO', PIER ANDREA;MIGLIORI, ALESSANDRO;FOCARDI, ETTORE
2004
Abstract
In the silicon tracker for the Compact Muon Solenoid experiment at the forthcoming Large Hadron Collider of CERN, each silicon sensor is connected to the front-end electronics by a pitch adapter, the structure of which consists of a fan of very thin chromium strips coated with a few microns aluminium deposition, on a glass support. The absence of contaminants in the depositions is of crucial importance for the electrical and mechanical reliability of the micro-bonding connections. The PIXE set-up of the Florence external micro-beam facility appeared to be suitable to analyse the metal deposition of an adapter, on which the micro-bonds had shown mechanical and electrical problems. Our measurements pointed out a significant copper contamination of the metal deposition on the faulty adapter, while no copper was detected in another one, which showed a correct behaviour at bonding. This suggests a possible role of Cu impurities in the encountered problems during micro-bonding.I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



