A HPTLC–densitometric method, based on an external standard approach, was developed in order to obtain a novel procedure for routine analysis of secoisolariciresinol diglucoside (SDG) in flaxseed with a minimum of sample pre-treatment. Optimization of TLC conditions for the densitometric scanning was reached by eluting HPTLC silica gel plates in a horizontal developing chamber. Quantitation of SDG was performed in single beam reflectance mode by using a computer-controlled densitometric scanner and applying a five-point calibration in the 1.00–10.00 g/spot range. As no sample preparation was required, the proposed HPTLC–densitometric procedure demonstrated to be reliable, yet using an external standard approach. The proposed method is precise, reproducible and accurate and can be employed profitably in place of HPLC for the determination of SDG in complex matrices.
High-performance thin-layer chromatographic–densitometric determination of secoisolariciresinol diglucoside in flaxseed / Silvia A. Coran;Valerio Giannellini;Massimo Bambagiotti-Alberti. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1045:(2004), pp. 217-222. [10.1016/j.chroma.2004.06.042]
High-performance thin-layer chromatographic–densitometric determination of secoisolariciresinol diglucoside in flaxseed
CORAN, SILVIA;GIANNELLINI, VALERIO;
2004
Abstract
A HPTLC–densitometric method, based on an external standard approach, was developed in order to obtain a novel procedure for routine analysis of secoisolariciresinol diglucoside (SDG) in flaxseed with a minimum of sample pre-treatment. Optimization of TLC conditions for the densitometric scanning was reached by eluting HPTLC silica gel plates in a horizontal developing chamber. Quantitation of SDG was performed in single beam reflectance mode by using a computer-controlled densitometric scanner and applying a five-point calibration in the 1.00–10.00 g/spot range. As no sample preparation was required, the proposed HPTLC–densitometric procedure demonstrated to be reliable, yet using an external standard approach. The proposed method is precise, reproducible and accurate and can be employed profitably in place of HPLC for the determination of SDG in complex matrices.File | Dimensione | Formato | |
---|---|---|---|
sdg.pdf
Accesso chiuso
Tipologia:
Altro
Licenza:
Tutti i diritti riservati
Dimensione
112.21 kB
Formato
Adobe PDF
|
112.21 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.