Measurements of optical properties carried out at visible and NIR wavelengths on many samples of Intralipid 20% showed a high stability and surprisingly small batch-to-batch variations. Measurements have been carried out in a short time interval using samples from nine different batches with expiry dates spreading over ten years. For the specific reduced scattering coefficient, the values we have obtained, averaged over the nine batches, are 25.9, 21.2, and 18.4 mm−1 at λ = 632.8, 751, and 833 nm, respectively, and the corresponding maximum deviations from the average were 2.2%, 1.1%, and 1.4%. For the absorption coefficient, we obtained values slightly smaller with respect to the absorption coefficient of pure water at 751 and 833 nm, and slightly larger at 632.8 nm. These results suggest that Intralipid 20% can be the first step towards a diffusive reference standard for tissue-simulating phantoms.

Intralipid: towards a diffusive reference standard foroptical tissue phantoms / P. Di Ninni; F. Martelli; G. Zaccanti. - In: PHYSICS IN MEDICINE AND BIOLOGY. - ISSN 0031-9155. - ELETTRONICO. - 56:(2011), pp. N21-N28. [10.1088/0031-9155/56/2/N01]

Intralipid: towards a diffusive reference standard foroptical tissue phantoms

MARTELLI, FABRIZIO;ZACCANTI, GIOVANNI
2011

Abstract

Measurements of optical properties carried out at visible and NIR wavelengths on many samples of Intralipid 20% showed a high stability and surprisingly small batch-to-batch variations. Measurements have been carried out in a short time interval using samples from nine different batches with expiry dates spreading over ten years. For the specific reduced scattering coefficient, the values we have obtained, averaged over the nine batches, are 25.9, 21.2, and 18.4 mm−1 at λ = 632.8, 751, and 833 nm, respectively, and the corresponding maximum deviations from the average were 2.2%, 1.1%, and 1.4%. For the absorption coefficient, we obtained values slightly smaller with respect to the absorption coefficient of pure water at 751 and 833 nm, and slightly larger at 632.8 nm. These results suggest that Intralipid 20% can be the first step towards a diffusive reference standard for tissue-simulating phantoms.
2011
56
N21
N28
P. Di Ninni; F. Martelli; G. Zaccanti
File in questo prodotto:
File Dimensione Formato  
Di_Ninni_et_al_PMB_0031-9155_56_2_N01.pdf

Accesso chiuso

Tipologia: Versione finale referata (Postprint, Accepted manuscript)
Licenza: Tutti i diritti riservati
Dimensione 455.87 kB
Formato Adobe PDF
455.87 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/627385
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 152
  • ???jsp.display-item.citation.isi??? 127
social impact