A large system of silicon strip detectors with double sided readout has been successfully commissioned over the course of the last year at the e+e− collider LEP. The readout of this 73 728 channel system is performed with custom designed VLSI charge sensitive amplifier chips (CAMEX64A). An overall point resolution of 12 μm on both sides has been acheived for the complete system. The most important difficulties during the run were beam losses into the detector, and a chemical agent deposited onto the electronics; however, the damage from these sources was understood and brought under control. This and other results of the 1991 data-taking run are described with special emphasis on the operational experience.

Operational experience with a large detector system using silicon strip detectors with double sided readout / G. Batignani;C. Bauer;H. Becker;B. Bloch-Devaux;J. Boudreau;D. Brown;F. Bosi;L. Bosisio;M. Carpinelli;J. Carr;P. Cattaneo;A. Ciocci;P. Coyle;R. Dell'Orso;H. Dietl;J. Drinkard;E. Focardi;F. Forti;M. Giorgi;T. Hansl-Kozanecka;D. Hauff;P. Holl;R.G. Jacobsen;E. Lancon;J. Lauber;A. Litke;G. Lutz;G. Lütjens;E. Mannelli;W. Männer;T. Mattison;M. McNeil;S. Menary;L. Moneta;H.G. Moser;B. Mours;R. Ossa;G. Parrini;S. Piccinini;G. Redlinger;D. Rizzi;G. Rizzo;L. Roos;D. Rousseau;G. Taylor;G. Tonelli;G. Triggiani;A.S. Schwarz;P. Schwemling;R. Settles;H. Seywerd;V. Sharma;L. Strüder;C. Vannini;P.G. Verdini;J. Walsh;G. Walterman;S. Walther;J. Wear;F. Weber. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - ELETTRONICO. - 326:(1993), pp. 183-188. [10.1016/0168-9002(93)90349-M]

Operational experience with a large detector system using silicon strip detectors with double sided readout

FOCARDI, ETTORE;
1993

Abstract

A large system of silicon strip detectors with double sided readout has been successfully commissioned over the course of the last year at the e+e− collider LEP. The readout of this 73 728 channel system is performed with custom designed VLSI charge sensitive amplifier chips (CAMEX64A). An overall point resolution of 12 μm on both sides has been acheived for the complete system. The most important difficulties during the run were beam losses into the detector, and a chemical agent deposited onto the electronics; however, the damage from these sources was understood and brought under control. This and other results of the 1991 data-taking run are described with special emphasis on the operational experience.
1993
326
183
188
G. Batignani;C. Bauer;H. Becker;B. Bloch-Devaux;J. Boudreau;D. Brown;F. Bosi;L. Bosisio;M. Carpinelli;J. Carr;P. Cattaneo;A. Ciocci;P. Coyle;R. Dell'Orso;H. Dietl;J. Drinkard;E. Focardi;F. Forti;M. Giorgi;T. Hansl-Kozanecka;D. Hauff;P. Holl;R.G. Jacobsen;E. Lancon;J. Lauber;A. Litke;G. Lutz;G. Lütjens;E. Mannelli;W. Männer;T. Mattison;M. McNeil;S. Menary;L. Moneta;H.G. Moser;B. Mours;R. Ossa;G. Parrini;S. Piccinini;G. Redlinger;D. Rizzi;G. Rizzo;L. Roos;D. Rousseau;G. Taylor;G. Tonelli;G. Triggiani;A.S. Schwarz;P. Schwemling;R. Settles;H. Seywerd;V. Sharma;L. Strüder;C. Vannini;P.G. Verdini;J. Walsh;G. Walterman;S. Walther;J. Wear;F. Weber
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/638309
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 13
social impact