The ALEPH Vertex Detector (VDET) has been upgraded for the second phase of LEP running. The new version still uses double sided silicon strip detectors, fabricated with the same technology as the previous one, but the upgraded one is twice as long and has about half passive material in the tracking volume. Furthermore the readout electronics is now radiation hard (MX7-RH chips). An almost complete version of the upgraded VDET was installed in ALEPH during a three week LEP technical stop and took data in November 1995 during the LEP run at 130 GeV. The new detector worked well showing high signal over noise ratio and good efficiency. The point resolution measured during this run, using high momentum muons, 13 μm in the τ - φ view and 21 μm in the τ - z view, is dominated by the alignment precision, due to the low statistics available for this short LEP run. This result is however acceptable, since for lower momentum charged particle, the multiple scattering gives a significant contribution to the final impact parameter resolution. A better resolution has been achieved in the next run, when an initial period at the Z peak has been foreseen to calibrate and align the whole detector.

Performance of the Aleph upgraded silicon vertex detector / D. Creanza;M. de Palma;M. Girone;G. Maggi;G. Selvaggi;L. Silvestris;G. Raso;P. Tempesta;M. Burns;P. Coyle;C. Engster;M. Frank;L. Moneta;M. Wachnik;A. Wagner;J. Zaslavsky;E. Focardi;G. Sguazzoni;G. Parrini;E. Scarlini;A. Halley;V. O'Shea;C. Raine;G. Barber;W. Cameron;P. Dornan;D. Gentry;N. Konstantinidis;A. Moutoussi;J. Nash;D. Price;A. Stacey;L.W. Toudup;M.I. Williams;M. Billault;A. Bonissent;G. Bujosa;D. Calvet;J. Carr;C. Diaconu;P.E. Blanc;J.J. Destelle;P. Karst;P. Payre;D. Rousseau;M. Thulasidas;H. Dietl;H.-G. Moser;R. Settles;H. Seywerd;G. Waltermann;S. Bettarini;F. Bosi;R. Dell'Orso;A. Messineo;A. Profeti;G. Rizzo;P.G. Verdini;J. Walsh;J.P. Bizzell;P.D. Maley;J.C. Thompson;A.E. Wright;S. Black;H.Y. Kim;L. Bosisio;J. Putz;J. Rothberg;S. Wasserbaech;P. Elmer. - In: NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS. - ISSN 0920-5632. - ELETTRONICO. - 54:(1997), pp. 317-322. [10.1016/S0920-5632(97)00129-1]

Performance of the Aleph upgraded silicon vertex detector

FOCARDI, ETTORE;SCARLINI, ENRICO;
1997

Abstract

The ALEPH Vertex Detector (VDET) has been upgraded for the second phase of LEP running. The new version still uses double sided silicon strip detectors, fabricated with the same technology as the previous one, but the upgraded one is twice as long and has about half passive material in the tracking volume. Furthermore the readout electronics is now radiation hard (MX7-RH chips). An almost complete version of the upgraded VDET was installed in ALEPH during a three week LEP technical stop and took data in November 1995 during the LEP run at 130 GeV. The new detector worked well showing high signal over noise ratio and good efficiency. The point resolution measured during this run, using high momentum muons, 13 μm in the τ - φ view and 21 μm in the τ - z view, is dominated by the alignment precision, due to the low statistics available for this short LEP run. This result is however acceptable, since for lower momentum charged particle, the multiple scattering gives a significant contribution to the final impact parameter resolution. A better resolution has been achieved in the next run, when an initial period at the Z peak has been foreseen to calibrate and align the whole detector.
1997
54
317
322
D. Creanza;M. de Palma;M. Girone;G. Maggi;G. Selvaggi;L. Silvestris;G. Raso;P. Tempesta;M. Burns;P. Coyle;C. Engster;M. Frank;L. Moneta;M...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/638710
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact