We report the results of two beam tests performed in July and September 1995 at CERN using silicon microstrip detectors of various types: single sided, double sided with small-angle stereo strips, double sided with orthogonal strips, double sided with pads. For the read-out electronics, use was made of Preshape32, Premux 128 and VA1 chips. The signal-to-noise ratio and the resolution of the detectors was studied at different incident angles of the incoming particles and for different values of the detector bias voltage. The goal of these tests was to check and improve the performances of the prototypes for the CMS Central Detector.

Beam test results for single- and double-sided silicon detector prototypes of the CMS central detector / O Adriani;E Babucci;N Bacchetta;G Bagliesi;P Bartalini;A Basti;G.M Bilei;D Boemi;L Borrello;F Bosi;R Castaldi;G Castellini;E Catacchini;U Cazzola;B Checcucci;C Civinini;D Creanza;R D'Alessandro;M De Palma;R Dell'Orso;R Della Marina;L Fiore;E Focardi;A Gabbanini;A Giassi;A Giraldo;L Gorn;M Loreti;G Maggi;G Mantovani;M Meschini;A Messineo;S My;G Parrini;M Pieri;F Raffaelli;G Raso;A Santocchia;G Selvaggi;L Servoli;L Silvestris;A Skassyrskaia;F Szoncso;P Tempesta;M Tesi;G Tonelli;C Vannini;P.G Verdini;R Wheadon. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - ELETTRONICO. - 396:(1997), pp. 76-92. [10.1016/S0168-9002(97)00750-X]

Beam test results for single- and double-sided silicon detector prototypes of the CMS central detector

ADRIANI, OSCAR;D'ALESSANDRO, RAFFAELLO;FOCARDI, ETTORE;
1997

Abstract

We report the results of two beam tests performed in July and September 1995 at CERN using silicon microstrip detectors of various types: single sided, double sided with small-angle stereo strips, double sided with orthogonal strips, double sided with pads. For the read-out electronics, use was made of Preshape32, Premux 128 and VA1 chips. The signal-to-noise ratio and the resolution of the detectors was studied at different incident angles of the incoming particles and for different values of the detector bias voltage. The goal of these tests was to check and improve the performances of the prototypes for the CMS Central Detector.
1997
396
76
92
O Adriani;E Babucci;N Bacchetta;G Bagliesi;P Bartalini;A Basti;G.M Bilei;D Boemi;L Borrello;F Bosi;R Castaldi;G Castellini;E Catacchini;U Cazzola;B Checcucci;C Civinini;D Creanza;R D'Alessandro;M De Palma;R Dell'Orso;R Della Marina;L Fiore;E Focardi;A Gabbanini;A Giassi;A Giraldo;L Gorn;M Loreti;G Maggi;G Mantovani;M Meschini;A Messineo;S My;G Parrini;M Pieri;F Raffaelli;G Raso;A Santocchia;G Selvaggi;L Servoli;L Silvestris;A Skassyrskaia;F Szoncso;P Tempesta;M Tesi;G Tonelli;C Vannini;P.G Verdini;R Wheadon
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/638722
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact