A maximum for the coefficient of performance (COPf) is verified for a temperature dif¬ference between reservoirs and the hot isotherm of a closed irre¬versible cyclical refrigerator working at steady state condi¬tions. A maximum also exists when the COPf is considered as a function only of a parameter depending on the thermal characteristics of the heat exchangers. The influence of the parameter and entropy generation on the COPf maxima is described
Irreversible refrigerators with isothermal heat exchanges / G. Grazzini. - In: INTERNATIONAL JOURNAL OF REFRIGERATION. - ISSN 0140-7007. - STAMPA. - 16:(1993), pp. 101-106.
Irreversible refrigerators with isothermal heat exchanges
GRAZZINI, GIUSEPPE
1993
Abstract
A maximum for the coefficient of performance (COPf) is verified for a temperature dif¬ference between reservoirs and the hot isotherm of a closed irre¬versible cyclical refrigerator working at steady state condi¬tions. A maximum also exists when the COPf is considered as a function only of a parameter depending on the thermal characteristics of the heat exchangers. The influence of the parameter and entropy generation on the COPf maxima is describedFile in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.