The aim of this research is to investigate the thermophysical behaviour of building envelope multi-layer components and assess the whole building–plant response. The investigation was carried out in two different phases. The first phase concerned the study of the dynamic response of building envelope multilayer components, by providing an improved implementation of the present European Standard UNI EN ISO 13786:2008. The proposed method allows one to determine the transient thermophysical performance of opaque building components that are associated with a thermal zone maintained at constant or variable air temperature. The variable internal air temperature can be associated with experimental data. The second phase consisted of a transient analysis of the above thermal zone with a conditioning plant working. The building plant simulations were carried out by EnergyPlus software. The method proposed, based on European standards, is particularly useful in the perspective of the Certification of the Energy Performance of the building–plant system, required by the European Union. It can provide a useful tool for developing an abacus of different envelope multi-layer component performances in order to support design choices.

Building–plant system energy sustainability. An approach for transient thermal performance analysis / C.Balocco; V.Gori; E.Marmonti; L.Citi. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - STAMPA. - 49:(2012), pp. 443-453. [10.1016/j.enbuild.2012.02.048]

Building–plant system energy sustainability. An approach for transient thermal performance analysis

BALOCCO, CARLA
;
2012

Abstract

The aim of this research is to investigate the thermophysical behaviour of building envelope multi-layer components and assess the whole building–plant response. The investigation was carried out in two different phases. The first phase concerned the study of the dynamic response of building envelope multilayer components, by providing an improved implementation of the present European Standard UNI EN ISO 13786:2008. The proposed method allows one to determine the transient thermophysical performance of opaque building components that are associated with a thermal zone maintained at constant or variable air temperature. The variable internal air temperature can be associated with experimental data. The second phase consisted of a transient analysis of the above thermal zone with a conditioning plant working. The building plant simulations were carried out by EnergyPlus software. The method proposed, based on European standards, is particularly useful in the perspective of the Certification of the Energy Performance of the building–plant system, required by the European Union. It can provide a useful tool for developing an abacus of different envelope multi-layer component performances in order to support design choices.
2012
49
443
453
C.Balocco; V.Gori; E.Marmonti; L.Citi
File in questo prodotto:
File Dimensione Formato  
Balocco&Alii_ENB2012(1).pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.62 MB
Formato Adobe PDF
1.62 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/639486
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact