A full-range off-line power supply based on a two-inductor resonant current-clamped DC-DC converter is presented in this paper. The converter's operation allows a zero voltage turn-on of the MOSFETs. Moreover, conduction losses are drastically reduced by the current clamping effect achieved by utilizing both the leakage and the magnetizing inductance of the transformer. As a result switching losses are nearly zero, while conduction losses are much lower than in conventional resonant inverters and a full-load high-line maximum efficiency η=86% is achieved for the entire power supply at a frequency operation in the hundreds of kilohertz range. The output voltage V0=16 V is regulated over the entire load range, that is for an output current I0 ranging from 0.2 A to 2 A and for both American and European standard input voltages
Full-range power supply based on a two-inductor resonant current-clamped (L/sup 2/R-CC) DC-DC converterProceedings of 1997 IEEE International Symposium on Circuits and Systems. Circuits and Systems in the Information Age ISCAS '97 / A. Liberatore;M. Bartoli;A. Reatti;M.K. Kazimierczuk. - ELETTRONICO. - 2:(1997), pp. 873-876. (Intervento presentato al convegno Circuits and Systems, 1997. ISCAS '97., Proceedings of 1997 IEEE International Symposium on) [10.1109/ISCAS.1997.621852].
Full-range power supply based on a two-inductor resonant current-clamped (L/sup 2/R-CC) DC-DC converterProceedings of 1997 IEEE International Symposium on Circuits and Systems. Circuits and Systems in the Information Age ISCAS '97
REATTI, ALBERTO;
1997
Abstract
A full-range off-line power supply based on a two-inductor resonant current-clamped DC-DC converter is presented in this paper. The converter's operation allows a zero voltage turn-on of the MOSFETs. Moreover, conduction losses are drastically reduced by the current clamping effect achieved by utilizing both the leakage and the magnetizing inductance of the transformer. As a result switching losses are nearly zero, while conduction losses are much lower than in conventional resonant inverters and a full-load high-line maximum efficiency η=86% is achieved for the entire power supply at a frequency operation in the hundreds of kilohertz range. The output voltage V0=16 V is regulated over the entire load range, that is for an output current I0 ranging from 0.2 A to 2 A and for both American and European standard input voltagesFile | Dimensione | Formato | |
---|---|---|---|
00621852.pdf
Accesso chiuso
Tipologia:
Altro
Licenza:
Tutti i diritti riservati
Dimensione
274.44 kB
Formato
Adobe PDF
|
274.44 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.