Abstract—A representative case study of potential earthquake-induced pounding between adjacent R/C frame buildings with insufficient separation gaps is examined in this paper. The height of the two examined buildings is the same, but their response is affected by considerable torsional pounding effects. An upgraded version of the traditional linear viscoelastic model for the numerical time-history analysis of the dynamic impact problem is proposed and implemented in the finite element model of the buildings. The results of the assessment enquiries carried out in current conditions, and a damped interconnection-based mitigation solution based on the incorporation of pressurized fluid-viscous dissipaters across the inadequate separation gaps, are presented. Evaluations of the benefits provided by the retrofit intervention, and some of its technical installation details, are finally offered.
Damped interconnection-based mitigation of seismic pounding between adjacent R/C buildings / Sorace, S; Terenzi, G. - In: INTERNATIONAL JOURNAL OF ENGINEERING AND TECHNOLOGY. - ISSN 1793-8236. - STAMPA. - 5(3):(2013), pp. 406-412. [10.7763/IJET.2013.V5.585]
Damped interconnection-based mitigation of seismic pounding between adjacent R/C buildings
TERENZI, GLORIA
2013
Abstract
Abstract—A representative case study of potential earthquake-induced pounding between adjacent R/C frame buildings with insufficient separation gaps is examined in this paper. The height of the two examined buildings is the same, but their response is affected by considerable torsional pounding effects. An upgraded version of the traditional linear viscoelastic model for the numerical time-history analysis of the dynamic impact problem is proposed and implemented in the finite element model of the buildings. The results of the assessment enquiries carried out in current conditions, and a damped interconnection-based mitigation solution based on the incorporation of pressurized fluid-viscous dissipaters across the inadequate separation gaps, are presented. Evaluations of the benefits provided by the retrofit intervention, and some of its technical installation details, are finally offered.File | Dimensione | Formato | |
---|---|---|---|
AbsEdimb12b.pdf
accesso aperto
Tipologia:
Altro
Licenza:
Open Access
Dimensione
23.75 kB
Formato
Adobe PDF
|
23.75 kB | Adobe PDF | |
IJET_Sorace-Terenzi_Y070-IJET.pdf
Accesso chiuso
Tipologia:
Altro
Licenza:
Open Access
Dimensione
681.85 kB
Formato
Adobe PDF
|
681.85 kB | Adobe PDF | Richiedi una copia |
585-Y070.pdf
Accesso chiuso
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Open Access
Dimensione
1.96 MB
Formato
Adobe PDF
|
1.96 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.